ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Optimization of Magnetic Sensor Configuration for JT-60SA Plasma Control

https://repo.qst.go.jp/records/72582
https://repo.qst.go.jp/records/72582
35ab9a53-124e-4d79-803f-b273224787cc
Item type 会議発表用資料 / Presentation(1)
公開日 2017-12-15
タイトル
タイトル Optimization of Magnetic Sensor Configuration for JT-60SA Plasma Control
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 武智, 学

× 武智, 学

WEKO 714882

武智, 学

Search repository
武智 学

× 武智 学

WEKO 714883

en 武智 学

Search repository
抄録
内容記述タイプ Abstract
内容記述 JT-60SA, which has fully super conducting coils, is designed and now being constructed for the sake of supplement ITER toward DEMO after about eighteen-years JT-60U operation. In order to obtain information for control of JT-60SA plasma and physics research on the plasma, many types of magnetic sensors are developed. Reconstruction of plasma last closed flux surface (LCFS) and position is most basic and important for the plasma operation and the assessment of a plasma performance. For JT-60SA, they will be reproduced with magnetic sensors by the method of Cauchy condition surface (CCS) as an inverse problem in real time. CCS method uses the magnetic field signals from magnetic probes and magnetic flux signals from flux loops for the Dirichlet and Neumann conditions, respectively, in addition to the poloidal coil current. Recently, precise CCS reconstruction method, which was developed by tuning the position and size of the CCS surface, achieved error less than one centimeter at LCFS and divertor strike point.
In order to determine the minimum number and adequate position of magnetic probes and flux loops, we access the accuracy of reconstruction by CCS method with various numbers of them.
The reconstruction was performed from start to end of the plasma discharge with plasma current from 0.2MA to 5.5MA. Requirement for reconstruction accuracy is set to be the error less than 1 cm at diverter hit point and LCFS not to contact with the wall. The simulation was performed with and without the noise of the magnetic sensor observed in JT-60U and estimated eddy current on the vacuum vessel (VV) and stabilizing plate (SP).
The minimum number of magnetic probe is decided as seventeen on VV and six on SP. In fact, seventeen probes will be used for CCS calculation. The minimum number of flux loop is decided as eighteen on VV and six on SP. Actually, nineteen loops will be used. However, we will install as many number of flux loop as possible because the replacement after the construction of tokamak is difficult.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The joint meeting of the 26th International Toki Conference (ITC-26) and The 11th Asia Plasma and Fusion Association Conference
発表年月日
日付 2017-12-05
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:38:12.941725
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3