WEKO3
アイテム
Improvement of Microwave Injection for Heavy Ion Production at Compact ECR Ion Source
https://repo.qst.go.jp/records/72518
https://repo.qst.go.jp/records/72518865dc71b-4ce3-40f5-a23c-a967ab43f38d
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-09 | |||||
タイトル | ||||||
タイトル | Improvement of Microwave Injection for Heavy Ion Production at Compact ECR Ion Source | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Muramatsu, Masayuki
× Muramatsu, Masayuki× Hamada, Kouta× Kato, Yushi× Takahasi, (AEC) Katsuyuki× Suzuki, (AEC) Taku× Hojo, Satoru× Kitagawa, Atsushi× 村松 正幸× 濱田 滉太× 加藤 裕史× 北條 悟× 北川 敦志 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected to enable : 1) carbon-ion production for medical use, 2) various ions with a charge-to-mass ratio of 1/3 for the existing linac injector, and 3) low cost for modification. A prototype compact electron cyclotron resonance ion source, named Kei3, based on Kei series has been developed to correspond to produce these various ions at National Institute of Radiological Sciences. The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. We investigated basic performance of the Kei3 source in a previous experiment. Maximum beam intensity of C 4+ , N 5+ , O 6+ and Ne 7+ were 565 μ A, 185 μ A, 99 μ A and 50.5 μ A, respectively. In order to increase a beam intensity of heavy ion such as argon, we modify the microwave injection. The rf shield in the plasma chamber was used as a tuner of a microwave. The rf shield was installed at the position of a mirror peak of injection side, and it can move 30 mm upstream from there. As a result, we found an optimal position of rf shield for production of highly charged Ar ion. In this paper, modification of microwave injection and ion production (e.g. carbon and aluminium ion) are described. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 17th International Conference on Ion Sources (ICIS2017) | |||||
発表年月日 | ||||||
日付 | 2017-10-18 | |||||
日付タイプ | Issued |