ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Proton-nucleus interactions in non-water materials for proton radiotherapy treatment planning

https://repo.qst.go.jp/records/72500
https://repo.qst.go.jp/records/72500
2fe3a051-f734-4193-a3ac-4ad94f649b28
Item type 会議発表用資料 / Presentation(1)
公開日 2017-10-26
タイトル
タイトル Proton-nucleus interactions in non-water materials for proton radiotherapy treatment planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 713998

Inaniwa, Taku

Search repository
稲庭 拓

× 稲庭 拓

WEKO 713999

en 稲庭 拓

Search repository
抄録
内容記述タイプ Abstract
内容記述 To exploit the advantages of proton beam therapy fully, it is necessary to perform three-dimensional treatment planning and optimization. A prerequisite for this is an algorithm for accurate dose calculation. Recently, Monte Carlo (MC)-based dose-calculation systems have been developed for proton radiotherapy treatment planning. The accuracy of the calculation have been confirmed by comparing the MC-simulated and the measured dose distributions in water. This may satisfy the need for proton radiotherapy treatment planning, since tissue heterogeneity is conventionally modeled as water with various densities to reproduce its stopping power, i.e., the stopping effective density. Dose calculation based on this approximation, however, can be erroneous due to the water nonequivalence of body tissues, mainly in nuclear interactions. In absolute dosimetry, similar errors have been reported to occur when, for convenience, solid phantom materials are used instead of water. These errors can be corrected by introducing a fluence correction factor, which is the predetermined ratio of dose-in-water to dose-to-water in the material. The fluence correction factor varies among beams, materials, and depths and can be specifically determined by MC simulation. The accuracy of the MC-based patient dose calculation as well as that of the fluence correction factor depends heavily on the validity of the nuclear model employed by the MC codes. The purpose of this study is to validate the nuclear model employed by Geant4 MC code for proton radiotherapy treatment planning. We performed the irradiation experiments with a 235-MeV proton beam using five non-water materials. These materials were placed in front of a water phantom to measure the planner integrated dose distribution (PIDD) behind the materials. An in-house parallel-plate ionization chamber was used for the measurements. The measured PIDDs were compared with the MC-simulated PIDDs for each non-water materials. We will report the results of the comparisons.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International conference on Monte Carlo techniques for medical applications (MCMA2017)
発表年月日
日付 2017-10-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:39:09.337575
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3