A Quantitation Approach for the Time Course of Mouse Leg Contracture Induced by Carbon-Ion Irradiation

https://repo.qst.go.jp/records/72412
https://repo.qst.go.jp/records/72412
90214b2f-5a96-41a7-97cc-39ed1fd7bdfe
Item type 会議発表用資料 / Presentation(1)
公開日 2017-08-14
タイトル
タイトル A Quantitation Approach for the Time Course of Mouse Leg Contracture Induced by Carbon-Ion Irradiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ueno, Megumi

× Ueno, Megumi

WEKO 713264

Ueno, Megumi

Search repository
Nakanishi, Ikuo

× Nakanishi, Ikuo

WEKO 713265

Nakanishi, Ikuo

Search repository
Matsumoto, Ken-ichiro

× Matsumoto, Ken-ichiro

WEKO 713266

Matsumoto, Ken-ichiro

Search repository
上野 恵美

× 上野 恵美

WEKO 713267

en 上野 恵美

Search repository
中西 郁夫

× 中西 郁夫

WEKO 713268

en 中西 郁夫

Search repository
松本 謙一郎

× 松本 謙一郎

WEKO 713269

en 松本 謙一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 A digitalization approach of time course of radiation induced leg contracture of mouse was proposed for quantifying radiation effect on an individual living mouse. The shortening leg length of mouse can be easily measured with a caliper/ruler and can become a very simple digitalized index of radiation effect. Female C3H mice were anesthetized by i.p. injection of pentobarbital. The left hind legs of mice were irradiated with single dose of 16–45 Gy of 290 MeV carbon-ion beam using 0, 50, or 117 mm binary filter (BF). The alternative right legs of mice were used as the control. The lengths of both hind legs of the mice were measured using digital caliper before irradiation and every one week after irradiation. Degree of leg contracture, ΔSt, at the time point, t, was estimated by subtraction of left irradiated leg length from right control leg length. The Eq. 1, which is originally an equation of T1-weighted signal recovery in NMR, was fitted on the daily time course of ΔSt, then two parameters, ΔSmax and Ts, were estimated.
ΔSt = ΔSmax × ( 1 – exp(t / Ts) )[1]
where ΔSmax is maximum degree of leg contracture, Ts is time of leg contracture. Effect of carbon-ion irradiation given on a living mouse was quantified by the ΔSmax and the Ts of leg contracture, and then compared to that of X-ray. A single radiation dose of 16 Gy carbon-ion beam could not induce leg shortening during 220 days after irradiation. A single dose of 24, 32, or 45 Gy made starting leg shortening. By 32 Gy irradiation, ΔSmax was largest for BF117 experiment then followed by X-ray > BF50 > BF0. The Ts was shortest for X-ray experiment, then followed by BF0 < BF50 ~ BF117. In this study, an equation for quantum spin relaxation system was successfully diverted to an evaluation of radio-biological response.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 1st QST International Symposium -Quantum Life Science-
発表年月日
日付 2017-07-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:40:07.418628
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3