ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Development of ultra-compact scanning system

https://repo.qst.go.jp/records/72331
https://repo.qst.go.jp/records/72331
32da883f-5e48-4f8c-848d-47d3c793f4b0
Item type 会議発表用資料 / Presentation(1)
公開日 2017-05-23
タイトル
タイトル Development of ultra-compact scanning system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furukawa, Takuji

× Furukawa, Takuji

WEKO 712366

Furukawa, Takuji

Search repository
古川 卓司

× 古川 卓司

WEKO 712367

en 古川 卓司

Search repository
抄録
内容記述タイプ Abstract
内容記述 For our particle therapy society, this 10-20 years was transition phase form the passive delivery to the scanning delivery. In this transition from passive delivery, scanning delivery needs to keep specifications of 1) capability to treat moving tumor, 2) same or better dose rate, and 3) better dose conformation. Thus, the development of scanning system has been focused on faster scanning and smaller beam size. As a result of development, our scanning system has been treating the patients including moving target in both NIRS and KCC. Treating moving tumor with fast rescanning was one of important milestone in our society. However, next step of the development is strongly required, which means compact system with lower cost while keeping system performance. For this purpose, we have developed ultra-compact scanning magnet, which is really revolutionary device. This brand-new magnet makes the scanning system amazingly compact from 8 m to 3.5 m. Further, this new scanning system can deliver the field size of 34 cm x 34 cm. Not only a conceptual design, a prototype of this magnet is already manufactured and tested with carbon ion beam. Results of the beam test were successful and suitable for clinical use. Since smaller beam size is also important issue, we newly designed the irradiation port having a movable nozzle for further reduction of beam size, cooperating with the range shifter-less system. In this presentation, we will report this brand-new scanning system, which will be installed upcoming facilities.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 56th Annual Conference of the Particle Therapy Co-operative Group (PTCOG56)
発表年月日
日付 2017-05-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:41:06.043140
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3