  1. 学会発表・講演等
  2. ポスター発表

EXPERIMENTAL INVESTIGATION ON DOSIMETRIC CHARACTERIZATION OF GAFCHROMIC EBT3 AND EBT-XD FILMS FOR CLINICAL CARBON ION BEAM

https://repo.qst.go.jp/records/72330
https://repo.qst.go.jp/records/72330
f3f7ccdc-c43d-4636-9438-e79b44523b3f
Item type 会議発表用資料 / Presentation(1)
公開日 2017-05-22
タイトル
タイトル EXPERIMENTAL INVESTIGATION ON DOSIMETRIC CHARACTERIZATION OF GAFCHROMIC EBT3 AND EBT-XD FILMS FOR CLINICAL CARBON ION BEAM
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 米内, 俊祐

× 米内, 俊祐

WEKO 712358

米内, 俊祐

Search repository
新井, 千夏

× 新井, 千夏

WEKO 712359

新井, 千夏

Search repository
下山, 薫

× 下山, 薫

WEKO 712360

下山, 薫

Search repository
FOURNIER-BIDOZ, Nathalie

× FOURNIER-BIDOZ, Nathalie

WEKO 712361

FOURNIER-BIDOZ, Nathalie

Search repository
米内 俊祐

× 米内 俊祐

WEKO 712362

en 米内 俊祐

Search repository
新井 千夏

× 新井 千夏

WEKO 712363

en 新井 千夏

Search repository
下山 薫

× 下山 薫

WEKO 712364

en 下山 薫

Search repository
FOURNIER−BIDOZ Nathalie

× FOURNIER−BIDOZ Nathalie

WEKO 712365

en FOURNIER−BIDOZ Nathalie

Search repository
抄録
内容記述タイプ Abstract
内容記述 INTRODUCTION:
Radiochromic film such as Gafchromic EBT3 and EBT-XD is very useful tool for 2-dimensional dosimetric measurements in radiotherapy, because it is a self-developing film and has very high spatial resolution. However, since it is known that its dose response depends on LET, considerable care has to be taken in ion beam radiotherapy. In this study, the dose responses of EBT3 and EBT-XD were experimentally investigated for clinical carbon ion beam at Heavy Ion Medical Accelerator in Chiba (HIMAC) and the relationship between the dose response and LET was shown.
MATERIALS AND METHODS:
The LET value of incident beam was changed with variable PMMA filters placed at the upstream of the film. Dose responses were investigated for 4 LET values between 12 and 169 keV/um and the LET dependency was investigated for additional 4 LET values. The absorbed dose and LET values were determined by measurements with a parallel-plate ionization chamber and Monte Carlo simulations with the PHITS code. The irradiated and unirradiated films were digitized 24 hour after irradiation with a commercial scanner, and pixel values of the red color channel were converted into a net optical density.
RESULTS:
Figure 1 shows measured dose response curves and its LET dependency of EBT3 shown as relative efficiency (RE) compared to 6-MV photon. The dose response of EBT-XD showed lower sensitivity compared to EBT3 as manufacturer specifications, but its tendency and the LET dependency were similar to EBT3. It was also confirmed that the repeatability was ~3% at a maximum when netOD is higher than 0.02, which was comparable to that for other radiation species.
CONCLUSION:
Dose responses of EBT3 and EBT-XD for clinical carbon ion beam were experimentally obtained. It was shown that EBT3 and EBT-XD can be applied to measurements of dose distributions by clinical carbon ion beam of which LET is known.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NEUDOS-13
発表年月日
日付 2017-05-15
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:41:06.693985
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3