ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Reliability monitoring of medical accelerator

https://repo.qst.go.jp/records/72321
https://repo.qst.go.jp/records/72321
2f68cf08-3cfa-4d22-91f3-05eb745b301e
Item type 会議発表用資料 / Presentation(1)
公開日 2017-05-15
タイトル
タイトル Reliability monitoring of medical accelerator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 福田, 茂一

× 福田, 茂一

WEKO 712297

福田, 茂一

Search repository
福田 茂一

× 福田 茂一

WEKO 712298

en 福田 茂一

Search repository
抄録
内容記述タイプ Abstract
内容記述 The reliability of the medical accelerators is required to be as high as possible. Because particle therapy accelerators (PTA) are more complex than Linac accelerators for conventional X-ray therapy, it is not easy to keep and maintain the stability. The standards of irradiation system have make a transition from the passive irradiation method to the scanning one. This means the connection between the accelerator system and the scanning irradiation system becomes stronger than that between the accelerator one and passive irradiation one. The displacement of the beam from the accelerator affects directly the position of the irradiation beam at the isocenter and may make the unexpected integrated dose distribution. So, the way to monitor the reliability of the PTA is required.
\nWe proposed the way to monitor the reliability of PTA with parameters of Availability, Failure Rate and Repair time as a index for reliability monitoring. We introduced these monitoring parameter to the HIMAC (Heavy Ion Medical Accelerator in Chiba) including ion sources, linear accelerators, synchrotrons and irradiation system and has started to monitor its reliability since 2014.
\nAll failures that occurred in a month have been listed with cause of failure, defective parts and downtime to calculate above parameters. If the trend of parameters shows low quality, the cause would be investigated and corrective action would be examined. This presentation will explain how we decided the parameters as reliability indexes and how we have used these, with the cycle of Monitor-Analysis-Correction- Evaluation that maintains and/or improves the accelerator reliability.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 56th Annual Conference of the Particl Therapy Co-Operative Group (PTCOG56)
発表年月日
日付 2017-05-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:41:13.126440
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3