Improvement of Quantitative Analysis Method of Tritium Using Hydrophobic Catalyst

https://repo.qst.go.jp/records/72285
https://repo.qst.go.jp/records/72285
062893e5-d105-48f0-ac33-47830202b762
Item type 会議発表用資料 / Presentation(1)
公開日 2017-04-19
タイトル
タイトル Improvement of Quantitative Analysis Method of Tritium Using Hydrophobic Catalyst
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 枝尾, 祐希

× 枝尾, 祐希

WEKO 711965

枝尾, 祐希

Search repository
岩井, 保則

× 岩井, 保則

WEKO 711966

岩井, 保則

Search repository
佐藤, 克美

× 佐藤, 克美

WEKO 711967

佐藤, 克美

Search repository
林, 巧

× 林, 巧

WEKO 711968

林, 巧

Search repository
枝尾 祐希

× 枝尾 祐希

WEKO 711969

en 枝尾 祐希

Search repository
岩井 保則

× 岩井 保則

WEKO 711970

en 岩井 保則

Search repository
佐藤 克美

× 佐藤 克美

WEKO 711971

en 佐藤 克美

Search repository
林 巧

× 林 巧

WEKO 711972

en 林 巧

Search repository
抄録
内容記述タイプ Abstract
内容記述 Various methods of tritium measurement have been applied depending on a chemical form of tritium. A method combined oxidation catalyst and water bubblers has been used as one of the most quantitative analysis methods for gaseous tritium. We previously developed a quantitative analysis system to measure gaseous tritium in a high accuracy using by an organic-based hydrophobic platinum catalyst. However, the previous tritium analysis system has a shortcoming that the organic-based catalyst has no resistance to a high temperature of more than 100oC, so that the system was not able to measure combustible gas such as tritiated hydrocarbons because the heat of reaction of hydrocarbons combustion on catalyst was large. Then, we developed a hydrophobic platinum catalyst having heat resisting property and high activity to measure various chemical forms of tritium. A new quantitative analysis system using by the hydrophobic catalyst enhanced the thermal durability performed as good as the previous system over wide temperature range. The developed tritium measurement system is applicable widely for various tritium measurements.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 29th Symposium on Fusion Technology
発表年月日
日付 2016-09-08
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:41:39.218919
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3