Design and Testing of Crowbar Protection System for the JT- 60SA Superconducting Magnet Power Supplies

https://repo.qst.go.jp/records/72162
https://repo.qst.go.jp/records/72162
12bfb867-dae7-44fa-8db1-92c6a43ef789
Item type 会議発表用資料 / Presentation(1)
公開日 2017-03-01
タイトル
タイトル Design and Testing of Crowbar Protection System for the JT- 60SA Superconducting Magnet Power Supplies
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zito, Pietro.

× Zito, Pietro.

WEKO 710569

Zito, Pietro.

Search repository
Lampasi, Alessandro.

× Lampasi, Alessandro.

WEKO 710570

Lampasi, Alessandro.

Search repository
Novello, Luca

× Novello, Luca

WEKO 710571

Novello, Luca

Search repository
Shimada, Katsuhiro

× Shimada, Katsuhiro

WEKO 710572

Shimada, Katsuhiro

Search repository
Matsukawa, Makoto

× Matsukawa, Makoto

WEKO 710573

Matsukawa, Makoto

Search repository
島田 勝弘

× 島田 勝弘

WEKO 710574

en 島田 勝弘

Search repository
松川 誠

× 松川 誠

WEKO 710575

en 松川 誠

Search repository
抄録
内容記述タイプ Abstract
内容記述 JT-60SA is a Superconducting Tokamak in the framework of the Broader Approach Agreement (BAA) between Europe and Japan. For this International Project, both the Italian National Agency for New Technology, Energy and Sustainable Economic Development (ENEA) and the French Alternative Energies and Comissariat à l’Energie Atomique et aux Energies alternatives (CEA) have to provide overall twelve AC/DC pulse poloidal superconducting magnet power supplies (almost all rated for ±20 kA and ±1 kV). Each of them is equipped with a crowbar protection system. The crowbar system’s first function is to carry the current that is flowing through the superconducting coils and protects the AC/DC power converter from over-voltages, internal/external severe faults and in case of earthquakes. The current capability type test of crowbar system required a maximum peak current of ±26 kA and a maximum specific energy I2t = 4,6 GA2s for TF SCMPS. Finally the crowbar system and DC bus-bars were subjected to seismic tests in laboratory.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 29th Symposium on Fusion Technology (SOFT2016)
発表年月日
日付 2016-09-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:43:03.562166
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3