Accurate measurement 234U/238U activity ratio and 236U/238U isotope ratio in 10-8 range using thermal ionization mass spectrometry

https://repo.qst.go.jp/records/72038
https://repo.qst.go.jp/records/72038
29377168-ed71-499a-bbdd-a49cd596d451
Item type 会議発表用資料 / Presentation(1)
公開日 2016-07-26
タイトル
タイトル Accurate measurement 234U/238U activity ratio and 236U/238U isotope ratio in 10-8 range using thermal ionization mass spectrometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 S.K.Sahoo

× S.K.Sahoo

WEKO 1038623

S.K.Sahoo

Search repository
H.Arae

× H.Arae

WEKO 1038624

H.Arae

Search repository
T.Aono

× T.Aono

WEKO 1038625

T.Aono

Search repository
Sahoo, Sarata

× Sahoo, Sarata

WEKO 1038626

en Sahoo, Sarata

Search repository
Hideki, Arae

× Hideki, Arae

WEKO 1038627

en Hideki, Arae

Search repository
Tatsuo, Aono

× Tatsuo, Aono

WEKO 1038628

en Tatsuo, Aono

Search repository
抄録
内容記述タイプ Abstract
内容記述 Variations in the isotope ratios 234U/238U, 235U/238U, and U-236 abundance of natural uranium samples (e.g., uranium ores), are known to exist due to various physical, chemical, mass fractionation, redox transitions, radioactive decay, radioactive disequilibrium, alpha-recoil, and neutron capture. Precise measurement of uranium isotope ratios with sufficient accuracy is a challenge to resolve the range of natural variation in a representative set of samples. 234U belongs to the 238U natural radioactive decay series, and at equilibrium, the abundance ratio, 234U/238U, corresponds to their half-lives, i.e. 54.8 x 10-6.

Uranium was chemically separated from uranium ore as well as some soil samples affected by Fukushima accident and its isotopic composition was measured using a thermal ionization mass spectrometer (TIMS). Chemical separation of U was carried out by two-column separation procedure using UTEVA resin and UTEVA resin. Since Japanese soil samples contain a large amounts of Fe and it makes U isotope ratio measurement difficult. Therefore, we separated U with UTEVA resin twice.

The TIMS (Phoenix, IsotopX, UK) used has nine Faraday cups collectors and a Daly ion-counting system detector positioned behind axial Faraday and WARP (wide aperture retardation potential) filter. The WARP filter is designed to suppress the tailing effect. Abundance sensitivity of 236U using NBS 030a was 5.86ppm. The limit of detection for 236U/238U measurements using Daly ion counting system with WARP is about 2x10-9 to 4x10-9. This was evaluated using certified natural uranium reference materials from University of Vienna in house standard in the order of 1.01x10-8. This method for uranium isotopic composition has been shown to significantly improve the precision and accuracy in analysis of environmental samples. Results will be discussed in detail during presentation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 7th International Conference on Radionuclide Metrology Low-Level Radioactivity Measurement Techniques
発表年月日
日付 2016-09-26
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:55:52.698978
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3