Design and performance of daily QA system for carbon ion therapy at NIRS

https://repo.qst.go.jp/records/71957
https://repo.qst.go.jp/records/71957
7fc8b4af-3d81-4459-b85a-5cd04aa0e895
Item type 会議発表用資料 / Presentation(1)
公開日 2016-07-11
タイトル
タイトル Design and performance of daily QA system for carbon ion therapy at NIRS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 早乙女, 直也

× 早乙女, 直也

WEKO 708692

早乙女, 直也

Search repository
古川, 卓司

× 古川, 卓司

WEKO 708693

古川, 卓司

Search repository
水島, 康太

× 水島, 康太

WEKO 708694

水島, 康太

Search repository
原, 洋介

× 原, 洋介

WEKO 708695

原, 洋介

Search repository
丹正, 亮平

× 丹正, 亮平

WEKO 708696

丹正, 亮平

Search repository
皿谷, 有一

× 皿谷, 有一

WEKO 708697

皿谷, 有一

Search repository
早乙女 直也

× 早乙女 直也

WEKO 708698

en 早乙女 直也

Search repository
古川 卓司

× 古川 卓司

WEKO 708699

en 古川 卓司

Search repository
水島 康太

× 水島 康太

WEKO 708700

en 水島 康太

Search repository
原 洋介

× 原 洋介

WEKO 708701

en 原 洋介

Search repository
丹正 亮平

× 丹正 亮平

WEKO 708702

en 丹正 亮平

Search repository
皿谷 有一

× 皿谷 有一

WEKO 708703

en 皿谷 有一

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since carbon ion deposits most of their energy in the last final millimeters of their trajectory, the accuracy of the beam energy/range is required for carbon ion treatment especially for using scanning method. Physical advantages of carbon ion are not only for the beam direction, but also for the lateral direction compare with conventional photon or proton beam. Although QA procedures are necessary for establishing safe and accurate dose delivery of any radiation therapy treatment modality, much high level of QA procedures are required for carbon-ion therapy. At the National Institute of Radiological Sciences (NIRS), we have been commissioning the rotating-gantry system for the carbon-ion radiotherapy. This rotating-gantry can transport heavy ions having 430 MeV/u to an isocenter with irradiation angles of over ±180° that is able to rotate around the patient so that the tumor can be irradiated from many directions. A three-dimensional pencil beam scanning irradiation system which is equipped with the rotating-gantry, provide the optimal use of physical characteristics of carbon-ion and to achieve accurate treatment. This irradiation system can provide the treatment of a moving target by fast scanning irradiation. A maximum scanning velocity is 100 mm/ms at isocenter. To ensure the treatment quality using such a complex system, calibration of the primary dose monitor, range check, dose rate check, machine safety check, and some mechanical tests should be performed efficiently. For this purpose, we have developed a measurement system dedicated for quality assurance (QA) of this gantry system. The system consists of an ionization chamber system and a scintillator system. For the ionization chamber system, a Farmer type ionization chamber is inserted into the center of a plastic water phantom. The thickness of the phantom could be changed so that employ both calibration of the output at entrance and output checking at center of the irradiation field. For the scintillator system, the ranges of beams are verified using a CCD camera and a scintillator. From the taken images, maximum gradient points are determined by some image processing and compared with reference data. In this paper, we describe consideration of the daily QA system for the rotating-gantry.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 12th European Conference on Accelerators in Applied Research and Technology (ECAART12)参加・発表
発表年月日
日付 2016-07-07
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:45:26.279445
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3