WEKO3
アイテム
QA team activities of Japan Carbon-ion Radiation Oncology Study Group
https://repo.qst.go.jp/records/71934
https://repo.qst.go.jp/records/71934bb2ef0d9-025c-494e-b064-ca5fe2922ffe
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-06-03 | |||||
タイトル | ||||||
タイトル | QA team activities of Japan Carbon-ion Radiation Oncology Study Group | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizuno, Hideyuki
× Mizuno, Hideyuki× Fukumura, Akifumi× Kanematsu, Nobuyuki× Yonai, Shunsuke× Shirai, Toshiyuki× Kanai, Tatsuaki× Yusa, Ken× Yanou, Toshihiro× Suga, Masaki× Mizota, Manabu× 水野 秀之× 福村 明史× 兼松 伸幸× 米内 俊祐× 白井 敏之× 金井 達明× 遊佐 顕× 矢能 稔啓× 壽賀 正城× 溝田 学 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Japan Carbon-ion Radiation Oncology Study Group (J-CROS) was established in 2014. The purpose of the group is to obtain clinical evidence through a multi-center clinical trial among participated facilities to show the efficiency of carbon-ion radiation therapy. In this trial, it is crucial to assure the uniformity of medical physics issue such as absolute dose used in each facility. J-CROS QA team was organized in 2015 so as it serves the purpose of enhancing the confidence that the clinical dosimetry is accurate and the facility QA procedures are adequate. The initial activity of the team was to settle on QA requirements. Those were as follows, 1. Having established QA program, 2. National protocol based beam calibration and dose specification, 3. Clear specification of RBE model, 4. QA of converting “CT number” to carbon “relative stopping power”, 5. Dose specification to volumes using the standard nomenclature of ICRU reports, 6. Patient anatomical and physiological changes during a fraction or over the course of treatment should be assessed. For the second activity, on-site dose audit was performed for several facility using water phantom. Facilities were requested to obtain CT image with the phantom and make plans as if the phantom is real patient prior to the on-site audit. The isocenter dose was measured by ionization chamber at on-site audit and compared with the calculated dose. By the end of 2015, on-site audit to 3 facilities were completed and the difference between measured and calculated dose was within ±3% for every facility. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 55th Particle Therapy Co-Operative Group | |||||
発表年月日 | ||||||
日付 | 2016-05-27 | |||||
日付タイプ | Issued |