Evaluation of scanned beam accuracy using a verification tool of 2D fluence distribution

https://repo.qst.go.jp/records/71933
https://repo.qst.go.jp/records/71933
bd521052-9dea-4f17-86e8-9c25cbe4663b
Item type 会議発表用資料 / Presentation(1)
公開日 2016-06-03
タイトル
タイトル Evaluation of scanned beam accuracy using a verification tool of 2D fluence distribution
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tansho, Ryohei

× Tansho, Ryohei

WEKO 708407

Tansho, Ryohei

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 708408

Furukawa, Takuji

Search repository
Hara, Yousuke

× Hara, Yousuke

WEKO 708409

Hara, Yousuke

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 708410

Mizushima, Kota

Search repository
Saotome, Naoya

× Saotome, Naoya

WEKO 708411

Saotome, Naoya

Search repository
Saraya, Yuichi

× Saraya, Yuichi

WEKO 708412

Saraya, Yuichi

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 708413

Shirai, Toshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 708414

Noda, Koji

Search repository
丹正 亮平

× 丹正 亮平

WEKO 708415

en 丹正 亮平

Search repository
古川 卓司

× 古川 卓司

WEKO 708416

en 古川 卓司

Search repository
原 洋介

× 原 洋介

WEKO 708417

en 原 洋介

Search repository
水島 康太

× 水島 康太

WEKO 708418

en 水島 康太

Search repository
早乙女 直也

× 早乙女 直也

WEKO 708419

en 早乙女 直也

Search repository
皿谷 有一

× 皿谷 有一

WEKO 708420

en 皿谷 有一

Search repository
白井 敏之

× 白井 敏之

WEKO 708421

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 708422

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have developed a verification tool of a 2D fluence distribution for evaluation of scanned beam accuracy. The 2D fluence distributions of all slices are measured and recorded with a beam position monitor using a multi-wire proportional chamber during irradiation. Using a beam irradiation pattern file, the verification tool calculates the 2D fluence distributions on the plane that the beam position monitor is located. Moreover, the tool evaluates the effect of the accuracy of scanned beam delivery on the 2D fluence distributions by comparing the measured fluence distributions with calculated ones. Fig. 1 shows an example result of the 2D fluence based verification. For the patient-specific QA of this irradiation, it was difficult to evaluate the dose distribution measured by the conventional method using a 2D ionization chamber and a water phantom, since the number of evaluated point was less than 10. We tried to apply the 2D fluence based verification as additional check of scanned beam delivery. The γ-analysis of the 2D fluence distribution of each slice passed the acceptable pass rate of 90% and the result helped us to confirm the beam irradiation accuracy for this patient. The verification tool of 2D fluence distribution is a useful to ensure accurate beam delivery for pencil beam scanning. We will present the method for utilization of this tool in more detail, which includes the calculation method using a pencil beam profile measured with the beam position monitor and the verification method of the measured fluence distribution accuracy.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 55th Annual Conference of the Particle Therapy Co-operative Group (PTCOG55)
発表年月日
日付 2016-05-27
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:45:43.185142
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3