Modeling of body tissues for Monte Carlo simulation of radiotherapy planned with conventional x-ray CT

https://repo.qst.go.jp/records/71929
https://repo.qst.go.jp/records/71929
a169dbc4-da7f-4928-88aa-7206bce9098f
Item type 会議発表用資料 / Presentation(1)
公開日 2016-06-02
タイトル
タイトル Modeling of body tissues for Monte Carlo simulation of radiotherapy planned with conventional x-ray CT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 708343

Kanematsu, Nobuyuki

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 708344

Inaniwa, Taku

Search repository
Nakao, Minoru

× Nakao, Minoru

WEKO 708345

Nakao, Minoru

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 708346

en 兼松 伸幸

Search repository
稲庭 拓

× 稲庭 拓

WEKO 708347

en 稲庭 拓

Search repository
中尾 稔

× 中尾 稔

WEKO 708348

en 中尾 稔

Search repository
抄録
内容記述タイプ Abstract
内容記述 For accurate Monte Carlo simulation of radiotherapy, CT number of patient image is converted to mass density and elemental composition using functions or tables that are calibrated specifically for the relevant x-ray CT system. This study proposes an alternative and more practical approach of two-step conversion. Using the latest compilation of standard tissues for the reference adult male and female phantoms, we defined the representative tissues per density region by averaging mass density and composition for the regional tissues. We then formulated polyline relations between mass density and electron density, stopping-power ratio and elemental densities by connecting those of the representative tissues and compared with the preceding formulations in the literature. We also formulated a procedure of stoichiometric calibration for the first-step conversion and demonstrated the two-step CT-number conversion for an ideal x-ray CT model of 80-keV photons. For the standard tissues, there was generally high correlation between mass density and the other densities except of C and O for light spongiosa tissues occupying 1% of body mass. The polylines fitted to the dominant tissues and were generally consistent with the preceding formulations. The two-step conversion procedure was demonstrated to be practical and will potentially facilitate Monte Carlo simulation for treatment planning and for retrospective analysis of treatment plans with little impact on the management of planing CT systems.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 55th Annual Conference of the Particle Therapy Co-operative Group
発表年月日
日付 2016-05-27
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:45:46.714000
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3