Commissioning of the scanning irradiation system at KCC

https://repo.qst.go.jp/records/71928
https://repo.qst.go.jp/records/71928
86555e3f-594b-45f9-a5e3-325dbdb9dac8
Item type 会議発表用資料 / Presentation(1)
公開日 2016-05-31
タイトル
タイトル Commissioning of the scanning irradiation system at KCC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 早乙女, 直也

× 早乙女, 直也

WEKO 708333

早乙女, 直也

Search repository
古川, 卓司

× 古川, 卓司

WEKO 708334

古川, 卓司

Search repository
原, 洋介

× 原, 洋介

WEKO 708335

原, 洋介

Search repository
皿谷, 有一

× 皿谷, 有一

WEKO 708336

皿谷, 有一

Search repository
水島, 康太

× 水島, 康太

WEKO 708337

水島, 康太

Search repository
早乙女 直也

× 早乙女 直也

WEKO 708338

en 早乙女 直也

Search repository
古川 卓司

× 古川 卓司

WEKO 708339

en 古川 卓司

Search repository
原 洋介

× 原 洋介

WEKO 708340

en 原 洋介

Search repository
皿谷 有一

× 皿谷 有一

WEKO 708341

en 皿谷 有一

Search repository
水島 康太

× 水島 康太

WEKO 708342

en 水島 康太

Search repository
抄録
内容記述タイプ Abstract
内容記述 The treatment with a scanned carbon-ion beam was started at December 2015 at Kanagawa Cancer Center. We combined a compact dissemination treatment system of carbon-ion therapy and the pencil beam 3D scanning technique designed by the National Institute of Radiological Sciences (NIRS). The treatment experience with the carbon-ion scanning technique was the second in the country following NIRS. The basic design of the irradiation system was followed NIRS system. The basic parameters of the scanning system are described as follows. To obtain the range of more than 300 mm, the maximum energy is chosen as 430 MeV/u. The maximum field size is 220x220 mm2 for the transverse directions. The treatment for the moving target such as lung and liver is available with respiratory-gated and rescanning technique. The commissioning of the irradiation system was performed from summer of 2015 through collaboration with NIRS. The following measurement and verification related to beam delivery properties were carried out for 11 energies (140-430MeV/n): verification of the dose monitor linearity, measurement of integral depth dose and range, measurement of spot size and verification of the position accuracy, performed dose monitor calibration, and verification of the dose calculation accuracy. We will present the result of the commissioning in more detail.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 55th Annual Conference of the Particle Therapy Co-operative Group (PTCOG55)参加・発表
発表年月日
日付 2016-05-27
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:45:47.911689
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3