Design of superconducting magnets for a compact carbon gantry

https://repo.qst.go.jp/records/71844
https://repo.qst.go.jp/records/71844
7a1e8848-d8b8-42ca-b2bc-778514718c3b
Item type 会議発表用資料 / Presentation(1)
公開日 2015-10-22
タイトル
タイトル Design of superconducting magnets for a compact carbon gantry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Iwata, Yoshiyuki

× Iwata, Yoshiyuki

WEKO 707385

Iwata, Yoshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 707386

Noda, Koji

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 707387

Shirai, Toshiyuki

Search repository
岩田 佳之

× 岩田 佳之

WEKO 707388

en 岩田 佳之

Search repository
野田 耕司

× 野田 耕司

WEKO 707389

en 野田 耕司

Search repository
白井 敏之

× 白井 敏之

WEKO 707390

en 白井 敏之

Search repository
抄録
内容記述タイプ Abstract
内容記述 For widespread use of rotating gantries for carbon radiotherapy, we designed a new compact gantry. This new gantry consists of three combined-function superconducting-magnets having a bending angle of 90 degrees. The dipole field of the superconducting magnets is set to be Bmax=5.02 Tesla, corresponding to a bending radius of 1.32 m for transporting carbon ions having kinetic energy of 430 MeV/u. The superconducting magnet also has three independent super-conducting quadrupole-coils, which are to be winded inside of the dipole coil for beam focusing. The dipole and quadrupole coils are electrically isolated in the magnet, and connected to independent power supplies, so that each field component can be independently excited. Having used the combined-function superconducting magnets, the size of the rotating gantry would become very compact; the length and radius are 5.1 m and 4.0 m, respectively. The magnetic field distributions of the super-conducting magnets were calculated with a three-dimensional electromagnetic field solver, Opera-3d code. With calculated fields, the superconducting coils were designed, so as to obtain uniform field distributions. In this paper, the design of this compact rotating gantry as well as the superconducting magnets is presented.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International conference on magnet technology 24 (MT24)
発表年月日
日付 2015-10-20
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:46:44.194637
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3