ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

A patient-specific QA procedure for moving target irradiation in scanned ion therapy

https://repo.qst.go.jp/records/71829
https://repo.qst.go.jp/records/71829
75bd311a-42a5-4602-bf53-0cfbbdcd55f4
Item type 会議発表用資料 / Presentation(1)
公開日 2015-09-25
タイトル
タイトル A patient-specific QA procedure for moving target irradiation in scanned ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hara, Yousuke

× Hara, Yousuke

WEKO 707203

Hara, Yousuke

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 707204

Furukawa, Takuji

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 707205

Mizushima, Kota

Search repository
Noda, Koji

× Noda, Koji

WEKO 707206

Noda, Koji

Search repository
Saotome, Naoya

× Saotome, Naoya

WEKO 707207

Saotome, Naoya

Search repository
Saraya, Yuichi

× Saraya, Yuichi

WEKO 707208

Saraya, Yuichi

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 707209

Shirai, Toshiyuki

Search repository
Tansho, Ryohei

× Tansho, Ryohei

WEKO 707210

Tansho, Ryohei

Search repository
原 洋介

× 原 洋介

WEKO 707211

en 原 洋介

Search repository
古川 卓司

× 古川 卓司

WEKO 707212

en 古川 卓司

Search repository
水島 康太

× 水島 康太

WEKO 707213

en 水島 康太

Search repository
野田 耕司

× 野田 耕司

WEKO 707214

en 野田 耕司

Search repository
早乙女 直也

× 早乙女 直也

WEKO 707215

en 早乙女 直也

Search repository
皿谷 有一

× 皿谷 有一

WEKO 707216

en 皿谷 有一

Search repository
白井 敏之

× 白井 敏之

WEKO 707217

en 白井 敏之

Search repository
丹正 亮平

× 丹正 亮平

WEKO 707218

en 丹正 亮平

Search repository
抄録
内容記述タイプ Abstract
内容記述 Three-dimensional (3D) pencil-beam scanning technique has been utilized since 2011 in NIRS-HIMAC. Beam delivery system and treatment planning software (TPS) require dosimetric patient-specific QA to check each individual plan. Any change in the scanned beams will result in a significant impact on the irradiation dose. Therefore, patient-specific QA for moving target irradiation requires additional procedure.
In an additional QA for moving target irradiation, we placed 2D ionization chamber on the PMMA plate tilted with respect to the beam axis. The PMMA plate was set on the stage of the moving phantom. The moving phantom was moved according to patient data. We measured the dose distribution for both the static target and the moving target. We compared the results for the moving target with those for the static targets by means of a gamma index analysis
In the additional patient-specific QA, the gamma analysis between the moving and static targets showed the good agreement. We confirmed that this new technique was a beneficial QA procedure for moving target irradiation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 2015 International Beam Instrumentation Conference (IBIC 2015)
発表年月日
日付 2015-09-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:46:54.487523
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3