ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Characteristic of the range verification system using scintillator and CCD camera system

https://repo.qst.go.jp/records/71748
https://repo.qst.go.jp/records/71748
e75a9d4d-1ce4-40d8-a236-13df19fa3a36
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-30
タイトル
タイトル Characteristic of the range verification system using scintillator and CCD camera system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Saotome, Naoya

× Saotome, Naoya

WEKO 706189

Saotome, Naoya

Search repository
Hara, Yousuke

× Hara, Yousuke

WEKO 706190

Hara, Yousuke

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 706191

Mizushima, Kota

Search repository
Tansho, Ryohei

× Tansho, Ryohei

WEKO 706192

Tansho, Ryohei

Search repository
Saraya, Yuichi

× Saraya, Yuichi

WEKO 706193

Saraya, Yuichi

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 706194

Furukawa, Takuji

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 706195

Shirai, Toshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 706196

Noda, Koji

Search repository
早乙女 直也

× 早乙女 直也

WEKO 706197

en 早乙女 直也

Search repository
原 洋介

× 原 洋介

WEKO 706198

en 原 洋介

Search repository
水島 康太

× 水島 康太

WEKO 706199

en 水島 康太

Search repository
丹正 亮平

× 丹正 亮平

WEKO 706200

en 丹正 亮平

Search repository
皿谷 有一

× 皿谷 有一

WEKO 706201

en 皿谷 有一

Search repository
古川 卓司

× 古川 卓司

WEKO 706202

en 古川 卓司

Search repository
白井 敏之

× 白井 敏之

WEKO 706203

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 706204

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
National Institute of Radiological Sciences have been commissioning the irradiation method that employs more than 200 multiple beam energies supplied by synchrotron instead of the energy degraders. The accuracy of the beam energy/range is required for heavy ion treatment especially for using scanning method. ICRU78 recommend checking the range constancy for daily QA. Therefore easy and simple range verification system is required. The purpose of this work is to develop range verification system using scintillator and CCD (charge-coupled device) camera and to estimate the accuracy of the range verification using the system.
Material and methods
Using proposed system, projected depth dose distribution could be provided by one measurement. A EJ-200 plastic scintillator block was selected for obtained pure tranceparent block. The scintillator was mounted in the black box in order to shade a light in the room. The CCD camera (Type BU-41L, 1360x1024 pixels, Bitran Corp., Japan) was installed perpendicular to the beam axis. Therefore two-dimensional image projected depth dose distribution is provided by measurement. Total 131 mono-energy carbon beams that are in the range from 56 to 332 MeV/n were tested. The range resolution test was performed using range shifter made by PMMA plate placed upstream of the system. Edge positions at the distal region that were detected by image processing were compared with expected position.
Result
Measurement time was about 9 minutes for 131 energy beams. Peak-entrance ratio was small due to quenching effect and absorption of the light within the scintillator block. The 1 mm range difference was clearly divided. Standard deviation of repeating measurement was less than 0.3 mm. The difference of fluence with normal treatment operation didn’t effect the range verification.
Conclusion
The range check system using scintillator and CCD have nice characteristics for range verification with short time.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 7th Korea-Japan Joint Meeting on Medical Physics
発表年月日
日付 2014-09-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:47:50.659534
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3