Evaluation of three-dimensional organ doses using polymer gel dosimeter in radiotherapy for uterine cervical cancer

https://repo.qst.go.jp/records/71719
https://repo.qst.go.jp/records/71719
ab3e7bdb-7da2-459d-a5b3-d84779880332
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-12
タイトル
タイトル Evaluation of three-dimensional organ doses using polymer gel dosimeter in radiotherapy for uterine cervical cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 青天目, 州晶

× 青天目, 州晶

WEKO 705744

青天目, 州晶

Search repository
米内, 俊祐

× 米内, 俊祐

WEKO 705745

米内, 俊祐

Search repository
小原, 哲

× 小原, 哲

WEKO 705746

小原, 哲

Search repository
佐野, ひろみ

× 佐野, ひろみ

WEKO 705747

佐野, ひろみ

Search repository
砂岡, 正良

× 砂岡, 正良

WEKO 705748

砂岡, 正良

Search repository
玉川, 学

× 玉川, 学

WEKO 705749

玉川, 学

Search repository
若月, 優

× 若月, 優

WEKO 705750

若月, 優

Search repository
唐澤, 久美子

× 唐澤, 久美子

WEKO 705751

唐澤, 久美子

Search repository
赤羽, 恵一

× 赤羽, 恵一

WEKO 705752

赤羽, 恵一

Search repository
島田, 義也

× 島田, 義也

WEKO 705753

島田, 義也

Search repository
al., et

× al., et

WEKO 705754

al., et

Search repository
青天目 州晶

× 青天目 州晶

WEKO 705755

en 青天目 州晶

Search repository
米内 俊祐

× 米内 俊祐

WEKO 705756

en 米内 俊祐

Search repository
小原 哲

× 小原 哲

WEKO 705757

en 小原 哲

Search repository
佐野 ひろみ

× 佐野 ひろみ

WEKO 705758

en 佐野 ひろみ

Search repository
砂岡 正良

× 砂岡 正良

WEKO 705759

en 砂岡 正良

Search repository
玉川 学

× 玉川 学

WEKO 705760

en 玉川 学

Search repository
若月 優

× 若月 優

WEKO 705761

en 若月 優

Search repository
唐澤 久美子

× 唐澤 久美子

WEKO 705762

en 唐澤 久美子

Search repository
赤羽 恵一

× 赤羽 恵一

WEKO 705763

en 赤羽 恵一

Search repository
島田 義也

× 島田 義也

WEKO 705764

en 島田 義也

Search repository
抄録
内容記述タイプ Abstract
内容記述 1. Introduction
Recent progresses on radiotherapy can provide benefits to patients, and survive for a long period. On the other hand, undesired irradiation to non-target healthy tissue adjacent to the target is theoretically unavoidable, secondary cancer risk is of interest to the survivors. In practice, the treatment planning system (TPS) plays an important role for reducing doses in organ at risk. However, it is doubtful whether the TPS can give accurate doses in the low dose region far from the target organ, in which the acute effects rarely occur but secondary cancers may occur. Therefore, in this study, non-target organ doses of pelvic field in 3D using anthropomorphic phantom and polymer gel dosimeter were acquired in radiotherapy for uterine cervical cancer, and compared to the TPS calculation.
\n2. Materials and methods
To evaluate 3D dose distribution directly in uterine cervical radiotherapy, the anthropomorphic phantom of a female pelvis was developed. Containers filled with polymer gel in the phantom simulate organs. Additionally, 4 or 5 glass dosimeters were set in each organ for the dose calibration. The standard treatment plan in Japan was created for the phantom as a patient by using the TPS in each external beam radiotherapy (EBRT) or intra-cavitary brachytherapy (ICBT). The 10Gy of EBRT was delivered to the whole pelvis with or without center shielding using a 10MV x-ray beam from CLINAC21EX. In ICBT, It was irradiated with Ir-192 sources using microSelectron-HDR. Gel dosimeters after irradiations were read with MRI, and the reading values were calibrated by the absorbed dose measured with glass dosimeters set in each organ. The measured 3D dose distributions compared with the TPS calculations.
\n3. Result
In case 30Gy of EBRT and 20Gy of center shielding EBRT were delivered, the dose of uterine corpus, bladder, and rectum, or sigmoid colon and ovary were exposed approximately total 30Gy or 50Gy as the average absorbed dose. In case 24Gy of ICBT at A point were delivered uterine corpus, bladder, and rectum, or sigmoid colon and ovary were exposed approximately total from10Gy to 20Gy or a few Gy as the average absorbed dose
\n4. Conclusion
This study shows the 3D dose distributions in the uterine cervical cancer radiotherapy by using the female phantom and gel dosimeters. These results could be the basis for the second cancer incidence.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ICRR2015
発表年月日
日付 2015-05-27
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:08.959812
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3