ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Effect of Time-of-Flight Information to Fill Lost-Frequency in Incomplete PET Geometry

https://repo.qst.go.jp/records/71711
https://repo.qst.go.jp/records/71711
6164eab3-8d49-4ed4-b0f0-a6b66e0d4c79
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-08
タイトル
タイトル Effect of Time-of-Flight Information to Fill Lost-Frequency in Incomplete PET Geometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 田島, 英朗

× 田島, 英朗

WEKO 776415

田島, 英朗

Search repository
山谷, 泰賀

× 山谷, 泰賀

WEKO 776416

山谷, 泰賀

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 776417

en Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 776418

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 The time-of-flight (TOF) information can improve image quality in positron emission tomography (PET). In addition, it is known that the TOF information can significantly reduce the occurrence of image artifacts in incomplete geometries such as partial ring PET. In this study, we apply TOF information to the dual-ring OpenPET geometry, in which low frequency components are missing. We analyzed the TOF projection data in the incomplete PET geometry. Compared with the non-TOF projection data, the TOF projection data have wide range of frequency component along the projection direction. The theoretical analysis showed that the TOF projection data can fill lost-frequency components in the gap region of the dual-ring OpenPET. Also, numerical simulation showed that the reconstructed images with the TOF information had lost-frequency components which were lost in the non TOF reconstruction images. Therefore, we concluded that the TOF information is theoretically and practically effective for filling lost-frequency regions in incomplete geometries.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine
発表年月日
日付 2015-06-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:47:05.285791
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3