Glow Curve Analysis of commercial Al2O3 ceramics plate (Kyocera corp., A476) to Charged Particle Beam

https://repo.qst.go.jp/records/71704
https://repo.qst.go.jp/records/71704
40de26ea-89ba-4664-ab52-85224ee4a3a8
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-04
タイトル
タイトル Glow Curve Analysis of commercial Al2O3 ceramics plate (Kyocera corp., A476) to Charged Particle Beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 古場, 裕介

× 古場, 裕介

WEKO 705598

古場, 裕介

Search repository
Fukuda, Shigekazu

× Fukuda, Shigekazu

WEKO 705599

Fukuda, Shigekazu

Search repository
al., et

× al., et

WEKO 705600

al., et

Search repository
古場 裕介

× 古場 裕介

WEKO 705601

en 古場 裕介

Search repository
福田 茂一

× 福田 茂一

WEKO 705602

en 福田 茂一

Search repository
抄録
内容記述タイプ Abstract
内容記述 The verifications of the irradiation field or dose distribution in the charged particle therapy require the measurements with high spatial resolution, because these distributions are precipitous and complex. Recently, it was reported that the commercial Al2O3 ceramics plate (Kyocera corp., A476) showed good TL characteristics and available as 2D dosimeter. This ceramic TLD was very easy to deal and low-cost device, and with high spatial resolution. In order to use this ceramic TLD in the charged particle therapy as the verification tools, we investigated the thermoluminescence characteristics of the ceramic TLD to charged particle beams. In this study, experiments of several charged-particle-beam irradiations were performed at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) in the National Institute of Radiological Sciences (NIRS). The glow curve of the ceramic TLD was measured using a photon counting unit and programmable heat controller. The glow curves were recorded from room temperature up to 400 deg.C at a heating rate of 0.1 deg.C/s in air. The glow peaks were located at 148 deg.C, 220 deg.C and 285 deg.C. The dose linearity of all peaks was very good, but the TL efficiencies of each peak showed different LET dependence effect. The TL efficiency of the peak located at 148 deg.C showed remarkable small LET dependency. Using this TL-peak property, the commercial ceramics plate A476 might be available to measure dose distributions in charged particle therapy.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 15th International Congress of Radiation Research
発表年月日
日付 2015-05-28
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:19.138987
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3