ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Current Status and Radiobiological Studies Using SPICE-NIRS Microbeam Irradiation System

https://repo.qst.go.jp/records/71683
https://repo.qst.go.jp/records/71683
002f887a-8f83-44ed-8ea4-933520212298
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-02
タイトル
タイトル Current Status and Radiobiological Studies Using SPICE-NIRS Microbeam Irradiation System
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Konishi, Teruaki

× Konishi, Teruaki

WEKO 705318

Konishi, Teruaki

Search repository
Kobayashi, Alisa

× Kobayashi, Alisa

WEKO 705319

Kobayashi, Alisa

Search repository
Oikawa, Masakazu

× Oikawa, Masakazu

WEKO 705320

Oikawa, Masakazu

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 705321

Furusawa, Yoshiya

Search repository
KN, Yu Peter

× KN, Yu Peter

WEKO 705322

KN, Yu Peter

Search repository
Yang, Gen

× Yang, Gen

WEKO 705323

Yang, Gen

Search repository
Shirakawa, Yoshiyuki

× Shirakawa, Yoshiyuki

WEKO 705324

Shirakawa, Yoshiyuki

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 705325

Uchihori, Yukio

Search repository
小西 輝昭

× 小西 輝昭

WEKO 705326

en 小西 輝昭

Search repository
小林 亜利紗

× 小林 亜利紗

WEKO 705327

en 小林 亜利紗

Search repository
及川 将一

× 及川 将一

WEKO 705328

en 及川 将一

Search repository
古澤 佳也

× 古澤 佳也

WEKO 705329

en 古澤 佳也

Search repository
白川 芳幸

× 白川 芳幸

WEKO 705330

en 白川 芳幸

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 705331

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Microbeams made possible to deliver a defined number of charged particles on a single cell with a resolution of a few micrometers, and are most advantageous for the field of radiation-induced nontargeted effects, so-called bystander effects that are considered to be one of the major effects in the low-dose region. Thus, microbeam technique is advantageous for investigating studies related to addition effect and risk of low dose in space radiation for astronauts and cosmonauts. Our microbeam irradiation system, the Single-Particle Irradiation system to CEll (SPICE) provides a 3.4 MeV proton microbeam focused with a quadrupole magnetic lens on an upward vertical beam line. At present, SPICE is the only proton microbeam facility in Japan at which a single ion single-cell irradiation can be performed on mammalian cells with stability and high throughput using an upward vertical beam of below 2-micrometer in diameter, focused with a magnetic quadrupole triplet lens. A variety of irradiation modes have been established for radiation-induced bystander effects, cytoplasm irradiation etc. Within this several years, we have focused on the radio-induced bystander effects, especially on the aspect on the damaging and protective bystander response and signaling between two different kinds of cells, such as 1) human lung cancer and normal cells, and 2) cancer stem-like cells, CSCs
and non stem-like cancer cells, NSCCs in human fibro-sarcoma HT1080 cells. We also expanded our studies to bystander effect in vivo using Zebrafish embryos for bystander effect induced adaptive response. Results on these topics will be also introduced in the presentation. SPICE has been administrated as a ’Joint-use facility for Collaborative Research’, and thus NIRS are accepting research proposal from researchers outside NIRS.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Congress of Radiation Research 2015
発表年月日
日付 2015-05-28
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:33.027910
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3