ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

γ-TDMG and Zn-yeast, Radiation Mitigators, Did Not Affect the Carbon-beam-induced Growth Inhibition of Xenograft Tumor on Mice

https://repo.qst.go.jp/records/71677
https://repo.qst.go.jp/records/71677
01b9715b-0498-4d64-8191-c8caf747e0b1
Item type 会議発表用資料 / Presentation(1)
公開日 2015-06-02
タイトル
タイトル γ-TDMG and Zn-yeast, Radiation Mitigators, Did Not Affect the Carbon-beam-induced Growth Inhibition of Xenograft Tumor on Mice
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Anzai, Kazunori

× Anzai, Kazunori

WEKO 705270

Anzai, Kazunori

Search repository
Ueno, Megumi

× Ueno, Megumi

WEKO 705271

Ueno, Megumi

Search repository
Matsumoto, Ken-ichiro

× Matsumoto, Ken-ichiro

WEKO 705272

Matsumoto, Ken-ichiro

Search repository
Takata, Jiro

× Takata, Jiro

WEKO 705273

Takata, Jiro

Search repository
安西 和紀

× 安西 和紀

WEKO 705274

en 安西 和紀

Search repository
上野 恵美

× 上野 恵美

WEKO 705275

en 上野 恵美

Search repository
松本 謙一郎

× 松本 謙一郎

WEKO 705276

en 松本 謙一郎

Search repository
高田 二郎

× 高田 二郎

WEKO 705277

en 高田 二郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Heavy ion radiotherapy has recently received increasing attention in the field of radiotherapy because heavy ion irradiation is more effective than other types of ionizing irradiation such as X-ray or γ-radiation. The carbon ion beam used in heavy ion irradiation releases a large amount of energy at the end of its range and enables the safe delivery of an effective dose of irradiation to tumors without damaging normal tissues. We have reported that γ-tocopherol-N,N-dimethylglycine ester (γ-TDMG) [1] and heat-treated zinc-yeast (Zn-yeast) [2] are potent radiation mitigators preventing bone marrow death of mice even when administered after whole-body irradiation of a near-lethal dose of 7.5 Gy X-rays.
In the present study, at first we examined if γ-TDMG and Zn-yeast are also effective to prevent bone marrow death of C3H mice against carbon-beams (290 MeV, SOBP 6 cm). γ-TDMG (100 mg/kg) or Zn-yeast (100 mg/kg) suspended in 0.5% methyl cellulose solution was injected i.p. after whole-body carbon-beam irradiation on the mice. As a result, we found that both mitigators reduced the mortality of the mice when administered i.p. after whole-body irradiation of 6.0 Gy carbon-beams.
Next, we examined if these mitigators affect the growth-control of xenograft tumors by carbon- beams. C3H mice were injected s.c. with RIF-1 cells at right thigh. When the tumors had reached a volume of 70-100 mm3, the mice were divided into four groups (carbon-beams ± and mitigators ± ). It was found that the local irradiation dose to appropriately inhibit the growth of the xenograft tumor is 8.0 Gy. The mitigators were administered to mice i.p immediately after irradiation. The tumor volume (V) was calculated as V (mm3) = length (mm) x width (mm)2/2. The observation was brought to an end when the tumors exceeded 1,000 mm3 in the volume or became severely necrotic.Both γ-TDMG and Zn-yeast did not reduce the inhibition effect of the carbon-beam treatment on the xenograft tumor growth. These findings suggest that the mitigators might be useful for the protection of normal tissues at the radiation therapy by carbon-beams.
[1] K. Anzai et. al. (2014) J. Radiat. Res. 55, 67-74.
[2] M. Ueno et. al. (2009) Radiat. Res. 172, 519-524.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 15th International Congress of Radiation Research (ICRR 2015)
発表年月日
日付 2015-05-28
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:37.304786
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3