ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Upgrade of the beam extraction control system for scanned carbon-ion therapy at HIMAC

https://repo.qst.go.jp/records/71661
https://repo.qst.go.jp/records/71661
aa205358-4fc0-45f2-80c7-210bde8beb41
Item type 会議発表用資料 / Presentation(1)
公開日 2015-05-27
タイトル
タイトル Upgrade of the beam extraction control system for scanned carbon-ion therapy at HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizushima, Kota

× Mizushima, Kota

WEKO 705102

Mizushima, Kota

Search repository
水島 康太

× 水島 康太

WEKO 705103

en 水島 康太

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract
In scanned carbon-ion therapy, the narrow beam is desired to reduce damage to healthy tissue around the tumor. Since the energy absorbers increase the beam size by the multiple scattering, the accelerator system must output therapy beams with various energies to perform irradiation without using them. In addition, it is also required that the beam-intensity control is reliable for all energies to ensure irradiation accuracy.
At the Heavy Ion Medical Accelerator in Chiba (HIMAC), multiple-energy operation has been developed to produce the carbon-ion beams with different energies of more than 200 steps between 48 and 430 MeV/u in a single cycle of the synchrotron. To put this operation to practical use, we have upgraded the beam-intensity control system at the HIMAC synchrotron and have introduced the fast beam chopper system in the high energy beam transport (HEBT). To verify the performance of our system, we carried out the irradiation experiments.
The accelerator system could change the output beam energy quickly. The beam intensity could be controlled as required from the irradiation control system. The ripple of the beam spill was low in the wide intensity range. The HEBT chopper system prevented the uncontrollable spilled beam, induced by the emittance growth during beam deceleration, delivering to the irradiation port.
We confirmed that the accelerator system can provide the beams meeting the therapy requirements for all available energies. We will report the experimental results of our system in our presentation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 54th Annual Conference of the Particle Therapy Co-Operative Group (PTCOG54)
発表年月日
日付 2015-05-21
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:46.876210
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3