ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Patient-specific QA for moving target irradiation with a scanned ion beam in NIRS-HIMAC

https://repo.qst.go.jp/records/71659
https://repo.qst.go.jp/records/71659
47d84cf5-a585-4aa3-bc93-72a3419916fc
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2015-05-26
タイトル
タイトル Patient-specific QA for moving target irradiation with a scanned ion beam in NIRS-HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference output
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 原, 洋介

× 原, 洋介

WEKO 705094

原, 洋介

Search repository
原 洋介

× 原 洋介

WEKO 705095

en 原 洋介

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Three-dimensional (3D) pencil-beam scanning technique has been utilized since 2011 at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Beam delivery system and treatment planning software (TPS) require dosimetric patient-specific QA to check each individual plan. Any change in the scanned beams will result in a significant impact on the irradiation dose. In particular, in moving target irradiation with a scanned ion beam, the interplay effect between the target motion and scanned beams is a problem, because this effect cause over or under dosage in the target volume. Therefore, patient-specific QA for moving target irradiation requires additional procedure.
Methods: In a conventional patient specific QA flow in NIRS-HIMAC, the planned dose distribution is converted to the dose distribution in the water phantom. After that, we perform the measurement and analysis. In the measurement, 2D ionization chamber with water column is used. In an additional QA for moving target irradiation, we placed 2D ionization chamber on the PMMA plate tilted with respect to the beam axis. The PMMA plate was set on the stage of the moving phantom. The moving phantom was moved according to patient data. We measured the dose distribution for both the static target and the moving target. We compared the results for the moving target with those for the static targets by means of a gamma index analysis
Results: In the conventional patient-specific QA, the measured dose distributions agreed well with those calculated by the TPS, and the QA criteria were satisfied in all measurements. In the additional patient-specific QA, the gamma analysis between the moving and static targets showed the good agreement.
Conclusions: We performed the additional patient-specific QA for moving target irradiation with a scanned ion beam. We confirmed that this new technique was a beneficial QA procedure for moving target irradiation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 54th Annual Conference of the Particle Therapy Co-Operative Group (PTCOG54)
発表年月日
日付 2015-05-20
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:48.225049
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3