A survey on the accuracy of whole-body counters operated in Fukushima after the nuclear disaster

https://repo.qst.go.jp/records/71643
https://repo.qst.go.jp/records/71643
2ab738d5-2a8d-4472-996f-f47bc961518d
Item type 会議発表用資料 / Presentation(1)
公開日 2015-04-27
タイトル
タイトル A survey on the accuracy of whole-body counters operated in Fukushima after the nuclear disaster
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 仲野, 高志

× 仲野, 高志

WEKO 704919

仲野, 高志

Search repository
谷, 幸太郎

× 谷, 幸太郎

WEKO 704920

谷, 幸太郎

Search repository
金, ウンジュ

× 金, ウンジュ

WEKO 704921

金, ウンジュ

Search repository
栗原, 治

× 栗原, 治

WEKO 704922

栗原, 治

Search repository
酒井, 一夫

× 酒井, 一夫

WEKO 704923

酒井, 一夫

Search repository
仲野 高志

× 仲野 高志

WEKO 704924

en 仲野 高志

Search repository
谷 幸太郎

× 谷 幸太郎

WEKO 704925

en 谷 幸太郎

Search repository
金 ウンジュ

× 金 ウンジュ

WEKO 704926

en 金 ウンジュ

Search repository
栗原 治

× 栗原 治

WEKO 704927

en 栗原 治

Search repository
酒井 一夫

× 酒井 一夫

WEKO 704928

en 酒井 一夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Significant amounts of radionuclides were released into the environment due to the Fukushima Daiichi nuclear power station accident in March 2011. These radionuclides were deposited on the ground of wide areas of eastern Japan and a number of evacuees still cannot return home because of relatively high air dose rates caused by radioactive caesium (Cs-134 and Cs-137) on the ground. Compared to external exposure, internal exposure is much smaller under current radiation situations in Fukushima. Internal dose measurements with whole-body counters (WBCs) have been continued since late June in 2011 and the number of subjects being examined exceeded two hundred thousand so far. To cope with these extensive measurements, many WBCs have been newly installed; most of them are standing -type WBCs (FASTSCAN, Canberra Inc., US). National Institute of Radiological Sciences was requested to check the accuracy of 36 WBCs in FY 2012 and 2013. This task was performed using a set of BOMAB phantoms, each of which contains Ba-133, Cs-137, Co-60 or water, separately. These phantoms imitate an adult male (177 cm in height and 70 kg in weight) and the activity amounts in the phantoms were certificated by Japan Calibration Service System (JCSS). As a result, the relative error to the BOMAB phantoms ranged from -15% to 15% for Cs-137 (36 WBCs) and Co-60 (33 WBCs). The relative error was distributed positive-negative symmetrically for Cs-137, whereas was biased to the negative side for Co-60. Some WBCs could not identify Co-60 and/or Ba-133 because these nuclides were not originally intended to measure. Significant problems were not found in the WBCs being examined; however, it is necessary to develop some system to maintain the accuracy of around 50 WBCs currently operated in Fukushima.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 国際学会IM2015(International Conference on Individual Monitoring of Ionising Radiation)
発表年月日
日付 2015-04-20
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:58.627675
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3