WEKO3
アイテム
Database structure modification of internal exposure management suited for Japanese alimentation behavior
https://repo.qst.go.jp/records/71591
https://repo.qst.go.jp/records/71591c53b1490-9e56-4108-92b6-8f576b19b906
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-12 | |||||
タイトル | ||||||
タイトル | Database structure modification of internal exposure management suited for Japanese alimentation behavior | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
長谷川, 慎
× 長谷川, 慎× Fujise, Daisuke× Yoshida, Yuki× Okuda, Yasuo× Kawaguchi, Isao× Kurihara, Osamu× Matsumoto, Masaki× Yoshinaga, Shinji× al., et× 長谷川 慎× 藤瀬 大助× 吉田 裕貴× 奥田 保男× 川口 勇生× 栗原 治× 松本 雅紀× 吉永 信治 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] After the Fukushima nuclear accident, the anxieties about radiation exposure by eating food are growing. Management of internal radiation exposure by food is indicated. The authors have examined a modification of the database structure of an internal exposure management tool that is used in Belarus after the Chernobyl accident to be suited for Japanese alimentation behavior. This poster aims to solve the problem left that the method to constitute a dish is complicated. [Methods] 1) The foodstuffs and the amount of the each ingestion of dish are stored in ‘Ingredients’ table to constitute ingesting dish in the old database structure. In the new database structure, the ingestion of foodstuffs and the recipe of the dish are stored to separate table. The amount of ingested natural and artificial radionuclides are estimated by using the ingestion of foodstuffs. 2) To take into consideration of the estimation with detection limit of the radioactivity inspection, the detection limit value is stored. [Results] This database structure modification makes it easy to constitute ingesting dish reflecting Japanese alimentation behavior. Also, the data amount is up to 97% reduced. The estimation of the internal radiation considering the detection limit is enabled. [Conclusion] This modification makes it easy to constitute ingesting dish reflecting Japanese alimentation behavior. Also, the amount of data is drastically reduced. The authors built an internal exposure management tool with higher usability than the original. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | ECR2015(第27回欧州放射線学会議) | |||||
発表年月日 | ||||||
日付 | 2015-03-04 | |||||
日付タイプ | Issued |