ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Advance of ICP-MS for ultra-trace Pu isotope measurements

https://repo.qst.go.jp/records/71590
https://repo.qst.go.jp/records/71590
0a883089-985c-41f8-927f-44efa1796854
Item type 会議発表用資料 / Presentation(1)
公開日 2015-03-12
タイトル
タイトル Advance of ICP-MS for ultra-trace Pu isotope measurements
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 鄭, 建

× 鄭, 建

WEKO 704077

鄭, 建

Search repository
Bu, Wenting

× Bu, Wenting

WEKO 704078

Bu, Wenting

Search repository
田上, 恵子

× 田上, 恵子

WEKO 704079

田上, 恵子

Search repository
内田, 滋夫

× 内田, 滋夫

WEKO 704080

内田, 滋夫

Search repository
鄭 建

× 鄭 建

WEKO 704081

en 鄭 建

Search repository
田上 恵子

× 田上 恵子

WEKO 704082

en 田上 恵子

Search repository
内田 滋夫

× 内田 滋夫

WEKO 704083

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 In recent years, there has been an increasing demand of ultra-trace determination of Pu isotopes in studies of radiation protection, safeguards and nuclear forensics, and in environmental studies, such as tracing the sources of radioactive contamination, revealing the transport process of aerosols in the atmosphere, and in study of the ongoing environmental changes, for instance, soil erosion and desertification. Conventionally, alpha spectrometry has usually been used for Pu measurement in various environmental samples. This method, however, normally required a tedious chemical separation procedure and long counting times (days to weeks). Moreover, alpha spectrometry cannot distinguish 239Pu and 240Pu due to the close alpha radiation energies (5.16 MeV and 5.17 MeV for 239Pu and 240Pu, respectively), thus cannot provide isotopic composition information. In contrast, mass spectrometry, especially ICP-MS, as an atom-counting approach that counts the atoms themselves, irrespective of their decay mode, specific activity, or half-life, is gradually replacing/has replaced alpha spectrometry as a main-stream technique for Pu isotopic analysis. Due to the strength of argon plasma source of ICP-MS, extremely high, almost 100% ionization efficiency can be achieved for Pu isotopes with a first ionization potential of 6.03 eV as calculated from the Saha equation, thus, highly sensitive determination of Pu isotopes can be realized. Recent development of ICP-MS techniques, especially the sector-field ICP-MS, has pushed the detection limit for analysis of Pu isotopes down to sub-fg level.
A new sector-field ICP-MS, Element XR equipped with the JET interface (Thermo Scientific, Germany) was installed in Research Center for Radiation Protection, National Institute of Radiological Sciences (NIRS) in March 2014. As this Element XR is first installed for actinides analysis in Japan, we made an investigation in detail on its analytical potential for Pu isotopes. Combining with high efficiency sample introduction systems (APEX-Q and Aridus II), exceptionally high sensitivity was obtained, achieving a detection limit at attogram (10-18 g) level, which is comparable to or even better than that of the accelerator mass spectrometry (AMS). This new sector-field ICP-MS now has been used for the determination of Pu isotopes in various environmental samples, such as sediments, seawater, soil and agricultural crops.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第16回環境放射能研究会
発表年月日
日付 2015-03-09
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:49:33.793629
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3