WEKO3
アイテム
Detector Response Modeling with Asymmetric 2D Gaussian Functions for GPU-Based Image Reconstruction of the Whole-Body Dual-Ring OpenPET
https://repo.qst.go.jp/records/71544
https://repo.qst.go.jp/records/715441b870d1e-2deb-4de5-8cb1-4948c11b26d8
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-11-18 | |||||
タイトル | ||||||
タイトル | Detector Response Modeling with Asymmetric 2D Gaussian Functions for GPU-Based Image Reconstruction of the Whole-Body Dual-Ring OpenPET | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
田島, 英朗
× 田島, 英朗× 吉田, 英治× 品地, 哲弥× 山谷, 泰賀× 田島 英朗× 吉田 英治× 品地 哲弥× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We are developing the OpenPET which can provide an open space to make the patient observable and accessible during PET measurements. One of the key technologies for realizing the OpenPET geometry is the DOI detectors because the geometry has many oblique LORs. Even if the DOI detectors reduce the blurring effect of the thick crystals, it is important to model the detector response function (DRF) in the reconstruction algorithm to achieve high spatial resolution images. In this study, therefore, we developed a new DRF model based on asymmetric 2D Gaussian functions perpendicular to the LOR for on-the-fly DRF calculation by GPUs during image reconstruction. In the proposed model, we separated the detector crystal into two parts: head and tail. The head part has the shape of a cube. We set the center position of the asymmetric 2D Gaussian function at the center of the head part. The parameters of the asymmetric 2D Gaussian functions were calculated according to the size of the head part and tail part components perpendicular to the LOR. The proposed model was implemented on GPUs using the CUDA framework. We compared the proposed model with a simple Gaussian model and a crystal subsampling model which is an analytical model. We found DRFs in the proposed method provided a similar shape to that in the analytical model. In addition, the proposed model could include the blurring effect. The anatomical model could represent only the effect of crystal shape, while the simple Gaussian model could represent only the blurring effect. Finally, the proposed method was applied for a prototype whole-body dual-ring OpenPET. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | IEEE NSS&MIC | |||||
発表年月日 | ||||||
日付 | 2014-11-13 | |||||
日付タイプ | Issued |