ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

GPU-accelerated Real-time Imaging System for the OpenPET Toward Tumor-tracking Radiotherapy

https://repo.qst.go.jp/records/71465
https://repo.qst.go.jp/records/71465
bfec0c81-adf8-4658-b1e4-e8ac4edc204e
Item type 会議発表用資料 / Presentation(1)
公開日 2014-06-05
タイトル
タイトル GPU-accelerated Real-time Imaging System for the OpenPET Toward Tumor-tracking Radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 田島, 英朗

× 田島, 英朗

WEKO 702663

田島, 英朗

Search repository
吉田, 英治

× 吉田, 英治

WEKO 702664

吉田, 英治

Search repository
品地, 哲弥

× 品地, 哲弥

WEKO 702665

品地, 哲弥

Search repository
Futada, Haruhiko

× Futada, Haruhiko

WEKO 702666

Futada, Haruhiko

Search repository
Nagata, Takeshi

× Nagata, Takeshi

WEKO 702667

Nagata, Takeshi

Search repository
羽石, 秀昭

× 羽石, 秀昭

WEKO 702668

羽石, 秀昭

Search repository
山谷, 泰賀

× 山谷, 泰賀

WEKO 702669

山谷, 泰賀

Search repository
田島 英朗

× 田島 英朗

WEKO 702670

en 田島 英朗

Search repository
吉田 英治

× 吉田 英治

WEKO 702671

en 吉田 英治

Search repository
品地 哲弥

× 品地 哲弥

WEKO 702672

en 品地 哲弥

Search repository
羽石 秀昭

× 羽石 秀昭

WEKO 702673

en 羽石 秀昭

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 702674

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing the OpenPET, which can provide an open space observable and accessible to the patient during positron emission tomography (PET) measurement. As one possible application of the OpenPET, we are aiming at tumor tracking by means of PET. The PET imaging normally takes several minutes for data acquisition, data transferring, image reconstruction, and displaying the image. On the other hand, our goal is to perform acquisition through displaying in less than a second. In this study, we proposed a real-time imaging system for the OpenPET and implemented on a small OpenPET prototype. In the proposed system, real-time reconstruction system was implemented on graphics processing unit (GPU) by the use of compute unified device architecture (CUDA). The one-pass 3D list-mode dynamic row-action maximum likelihood algorithm (LM-DRAMA) was employed for the reconstruction algorithm. In the real-time imaging system, the data transfer control system limits the event counts to be used in the reconstruction step and the reconstructed images are properly intensified by using the ratio of the used counts to the total counts. The prototype system showed that the real-time monitoring of a moving radioactive source with a frame rate of 2.0 frames per second and a delay of 2.1 s.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 19th real-time conference
発表年月日
日付 2014-05-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:50:56.808476
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3