Dose-delivery Time Structure on Biological Effectiveness in Charged Particle Therapy

https://repo.qst.go.jp/records/71421
https://repo.qst.go.jp/records/71421
22d18969-9a39-4de2-9cae-ddbc67318c44
Item type 会議発表用資料 / Presentation(1)
公開日 2014-02-26
タイトル
タイトル Dose-delivery Time Structure on Biological Effectiveness in Charged Particle Therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 稲庭, 拓

× 稲庭, 拓

WEKO 702205

稲庭, 拓

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 702206

Suzuki, Masao

Search repository
B, Hawkins Roland

× B, Hawkins Roland

WEKO 702207

B, Hawkins Roland

Search repository
稲庭 拓

× 稲庭 拓

WEKO 702208

en 稲庭 拓

Search repository
鈴木 雅雄

× 鈴木 雅雄

WEKO 702209

en 鈴木 雅雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 [Instructions]
Treatment plans of c-ion radiotherapy have been made on the assumption that the beams in one fraction are delivered instantaneously by neglecting the dose delivery time as well as the interruption time. However, in practical treatments, it takes 1-10 minutes or longer to deliver a fractional dose to a patient depending on the prescribed dose level, the dose delivery technique and the performance of the delivery system. Especially, the advanced therapeutic techniques such as a hypo-fractionation and a respiratory gating usually require more time to deliver a fractional dose than the conventional one. In addition, the dose delivery can be interrupted due to some reasons such as the necessity of a patient re-setup between fields in a treatment fraction and machine troubles. Cell killing tends to decrease with the fraction time because of sublethal damage repair (SLDR). Thus, it is important to investigate the quantity of SLDR during the fraction time and to evaluate the effecs of dose-delivery time structure on the biological effectiveness of therapeutic c-ion beams. In this study, the Microdosimetric Kinetic Model (MKM) was adopted to address this issue.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 FIRST合同国際シンポジウム「難治がんを克服する‐次世代の診断、治療が描く未来」
発表年月日
日付 2014-02-24
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:51:27.452989
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3