ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Evaluation of base materials of TL slab Dosimeter for heavy-ion radiotherapy

https://repo.qst.go.jp/records/71384
https://repo.qst.go.jp/records/71384
95e84185-a85f-488f-8579-41e5b3bfd6d5
Item type 会議発表用資料 / Presentation(1)
公開日 2013-12-03
タイトル
タイトル Evaluation of base materials of TL slab Dosimeter for heavy-ion radiotherapy
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 古場, 裕介

× 古場, 裕介

WEKO 701871

古場, 裕介

Search repository
眞正, 浄光

× 眞正, 浄光

WEKO 701872

眞正, 浄光

Search repository
玉津, 早駿

× 玉津, 早駿

WEKO 701873

玉津, 早駿

Search repository
福田, 茂一

× 福田, 茂一

WEKO 701874

福田, 茂一

Search repository
若林, 源一郎

× 若林, 源一郎

WEKO 701875

若林, 源一郎

Search repository
古場 裕介

× 古場 裕介

WEKO 701876

en 古場 裕介

Search repository
眞正 浄光

× 眞正 浄光

WEKO 701877

en 眞正 浄光

Search repository
玉津 早駿

× 玉津 早駿

WEKO 701878

en 玉津 早駿

Search repository
福田 茂一

× 福田 茂一

WEKO 701879

en 福田 茂一

Search repository
若林 源一郎

× 若林 源一郎

WEKO 701880

en 若林 源一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to measure a three-dimensional dose distribution in X-ray radiotherapy, we developed TL slab dosimeter with new TL phosphor Li3B7O12(Cu), which has Zeff = 7.42 and a density of 1.01 g/cm3 and synthetic resin as binder. We can measure a 3D dose distribution easily and reliably using this detector. This detector showed a promising tool for QA/QC in advanced X-ray radiotherapies such as IMRT etc. In heavy-ion radiotherapies which shape precipitous dose distributions, it is also necessary to measure 3D dose distribution easily. To use TL slab dosimeter in heavy-ion dosimetry, it is essential to measure its LET dependence sufficiently. And it is necessary to evaluate the dosimetric water equivalence of this dosimeter for heavy ions. Previous studies showed that the relative TL efficiency of this TL phosphor decreased to about 20% at the Bragg-peak of carbon 290 MeV/u beams and the stopping-power ratio of this dosimeter to water for carbon ions was 0.87. These results were not good for application in heavy-ion radiotherapy.
It was often reported that there is a relationship between the glow curve shape of general TLDs (such as LiF and BeO) and LET. Using this relationship of glow curve and LET, the relative TL efficiency can be corrected and we could apply TLDs to dose measurement in heavy-ion radiotherapies. In this study, in order to develop better TL slab dosimeter for heavy-ion radiotherapy using TL phosphors with the above characteristics, we evaluated the dosimetric water equivalence of several base materials for TL slab dosimeter. We chose several kinds of ceramics with heating resistance as the base material. We focused attention on stopping power, scattering power and nuclear cross section of these materials for heavy ions. We calculated these interactions using the Bethe formula, the Gottschalk formula and the Sihver formula. On the basis this evaluation we will develop the TL slab dosimeter for heavy-ion radiotherapy.
Key words: TLD, TL slab dosimeter, heavy-ion radiotherapy
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 HITSRS2013
発表年月日
日付 2013-05-15
日付タイプ Issued
戻る
0
views
See details
Views