A Proposed Helmet-PET with a Jaw Detector Enabling High-Sensitivity Brain Imaging

https://repo.qst.go.jp/records/71353
https://repo.qst.go.jp/records/71353
05e2ba84-137e-4e85-bc8e-f4483f763086
Item type 会議発表用資料 / Presentation(1)
公開日 2013-11-14
タイトル
タイトル A Proposed Helmet-PET with a Jaw Detector Enabling High-Sensitivity Brain Imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tashima, Hideaki

× Tashima, Hideaki

WEKO 701597

Tashima, Hideaki

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 701598

Ito, Hiroshi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 701599

Yamaya, Taiga

Search repository
田島 英朗

× 田島 英朗

WEKO 701600

en 田島 英朗

Search repository
伊藤 浩

× 伊藤 浩

WEKO 701601

en 伊藤 浩

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 701602

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 The advanced depth-of-interaction positron emission tomography (PET) detectors have been improved to provide three-dimensionally uniform detector resolution. These detectors allow a geometry that places the detectors very close to imaging subjects, because they can maintain high spatial resolution even in the peripheral region in the field-of-view (FOV) without loss of sensitivity. In this study, we are proposing a helmet-PET geometry consisting of a hemispheric-shaped detector and a jaw detector. The key points of the geometry are the closely positioned detectors and the detector covering the jaw. For each point in the FOV, we calculated the geometrical sensitivity as the relative coverage of the solid angle where the coincidence measurement was possible. We found that the hemispheric-shaped geometry had high sensitivity for the cerebrum region. In addition, the jaw detector significantly improved the sensitivity at the center region of the hemisphere, where the cerebellum is positioned during PET measurement. High sensitivity and quantitative accuracy for the cerebellum region are important especially for functional brain imaging because this region may be used as a reference value in kinetic analysis. Geometrical analysis showed that the proposed geometry has good potential for highly sensitive and accurate measurement of brain functions. In addition, numerical simulations showed the proposed geometry increases image quality especially for the central region.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors workshop
発表年月日
日付 2013-11-02
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:52:14.627419
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3