ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Impact of TOF information in OpenPET imaging

https://repo.qst.go.jp/records/71351
https://repo.qst.go.jp/records/71351
95fbdf02-19bf-4de1-bc50-3919c1d809c1
Item type 会議発表用資料 / Presentation(1)
公開日 2013-11-14
タイトル
タイトル Impact of TOF information in OpenPET imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tashima, Hideaki

× Tashima, Hideaki

WEKO 701581

Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 701582

Yamaya, Taiga

Search repository
田島 英朗

× 田島 英朗

WEKO 701583

en 田島 英朗

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 701584

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing an open-type PET geometry that we named OpenPET. One possible geometry is the dual-ring OpenPET, which consists of two detector rings separated by a gap for entrance of the radiation beam. The gap can also be used for different modalities such as X-ray CT to realize a simultaneous multi-modality system. In addition, the dual-ring OpenPET has an effect to enlarge the axial field-of-view. In our previous simulations and experiments the OpenPET imaging geometry was shown to be feasible by applying iterative reconstruction methods. However, the gap violates Orlov's completeness condition for accurate tomographic reconstruction. Therefore, the gap could lead to artifacts caused by lost low-frequency components in the projection data depending on the shapes of imaging subjects. In this study, we investigate the effect of time-of-flight (TOF) information, which is expected to compensate for the lost low-frequency components in OpenPET imaging. We simulated the dual-ring OpenPET geometry with a numerical phantom and analyzed frequency components of the reconstructed images. The result showed that the low-frequency components were not fully estimated in the gap region of the dual-ring OpenPET while those components were well recovered with the TOF information.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors workshop
発表年月日
日付 2013-11-02
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:52:15.975937
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3