Washout studies of in-beam rat imaging by the 2nd generation OpenPET prototype

https://repo.qst.go.jp/records/71338
https://repo.qst.go.jp/records/71338
c6f53bc5-a59b-4949-982e-457569315a85
Item type 会議発表用資料 / Presentation(1)
公開日 2013-11-13
タイトル
タイトル Washout studies of in-beam rat imaging by the 2nd generation OpenPET prototype
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirano, Yoshiyuki

× Hirano, Yoshiyuki

WEKO 701453

Hirano, Yoshiyuki

Search repository
et.al

× et.al

WEKO 701454

et.al

Search repository
平野 祥之

× 平野 祥之

WEKO 701455

en 平野 祥之

Search repository
抄録
内容記述タイプ Abstract
内容記述 In-beam positron emission tomography (PET) is expected to be suitable as an in situ dose verification technique in particle therapies. For accurate dose verification, washout of positron emitters should be corrected. In addition, the quantitative washout rate has a potential usefulness as a diagnostic index such as for blood flow and stage of cancer progression. In this work, therefore, we applied compartment analyses to in-beam PET data acquired by the 2nd generation small OpenPET prototype. The OpenPET is our original idea for the open-type PET geometries, which enables PET scanning during irradiation in particle therapies. Two rat brains and two rat thighs located at the field-of-view were irradiated by a 11C beam. Time activity curves of the irradiated field were measured immediately after the irradiations, and the washout rate was calculated based on the two-washout model (medium decay, k2m; slow decay, k2s) developed in a previous study of rabbit irradiation reported by Mizuno
et al. For brain irradiations, k2m and k2s were respectively, 0.37 and 0.008 [min-1]. For thigh irradiations, these were 0.34 and 0.008 [min-1]. These results were consistent with the rabbit study. Also k2m of brain irradiation was close to the washout rate in cerebral blood flow measurements by dynamic PET with 15O-water. Our present work suggested the k2m may be relevant to blood flow.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2013 IEEE NSS/MIC/PTSD
発表年月日
日付 2013-11-02
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:52:24.855164
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3