Comparison between SUVmax and SUVpeak of FDG uptake in pancreas cancer:Bland-Altman plot analysis

https://repo.qst.go.jp/records/71319
https://repo.qst.go.jp/records/71319
08d04ccc-08a2-4e93-989c-475c55636282
Item type 会議発表用資料 / Presentation(1)
公開日 2013-11-01
タイトル
タイトル Comparison between SUVmax and SUVpeak of FDG uptake in pancreas cancer:Bland-Altman plot analysis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 701180

Yoshikawa, Kyosan

Search repository
Ohashi, Seiya

× Ohashi, Seiya

WEKO 701181

Ohashi, Seiya

Search repository
Toubaru, Sachiko

× Toubaru, Sachiko

WEKO 701182

Toubaru, Sachiko

Search repository
Hasebe, Mitsuhiko

× Hasebe, Mitsuhiko

WEKO 701183

Hasebe, Mitsuhiko

Search repository
Tamura, Katsumi

× Tamura, Katsumi

WEKO 701184

Tamura, Katsumi

Search repository
Shiraishi, Takahiro

× Shiraishi, Takahiro

WEKO 701185

Shiraishi, Takahiro

Search repository
Tanimoto, Katsuyuki

× Tanimoto, Katsuyuki

WEKO 701186

Tanimoto, Katsuyuki

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 701187

Yamada, Shigeru

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 701188

Kandatsu, Susumu

Search repository
Zhang, Ming-Rong

× Zhang, Ming-Rong

WEKO 701189

Zhang, Ming-Rong

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 701190

Saga, Tsuneo

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 701191

Kamada, Tadashi

Search repository
吉川 京燦

× 吉川 京燦

WEKO 701192

en 吉川 京燦

Search repository
大橋 靖也

× 大橋 靖也

WEKO 701193

en 大橋 靖也

Search repository
桃原 幸子

× 桃原 幸子

WEKO 701194

en 桃原 幸子

Search repository
長谷部 充彦

× 長谷部 充彦

WEKO 701195

en 長谷部 充彦

Search repository
田村 克巳

× 田村 克巳

WEKO 701196

en 田村 克巳

Search repository
白石 貴博

× 白石 貴博

WEKO 701197

en 白石 貴博

Search repository
谷本 克之

× 谷本 克之

WEKO 701198

en 谷本 克之

Search repository
山田 滋

× 山田 滋

WEKO 701199

en 山田 滋

Search repository
神立 進

× 神立 進

WEKO 701200

en 神立 進

Search repository
張 明栄

× 張 明栄

WEKO 701201

en 張 明栄

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 701202

en 佐賀 恒夫

Search repository
鎌田 正

× 鎌田 正

WEKO 701203

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Adoption of metabolic imaging with F-18-FDG in staging and follow up of cancers needs tumor metabolism parameters like standardized uptake value (SUV). SUVmax,the value of the single voxel with the maximum intensity, avoids inter-observer differences, but a major drawback of SUVmax is its susceptibility to noise in the data. SUVpeak defined as the largest possible mean value of a 1 cm3 spherical VOI positioned within a tumor removes inter-observer variation and reduces the susceptibility to noise. In this study we compared SUVpeak against SUVmax of glucose metabolic activity of pancreas cancer, and assessed how much the SUVpeak was likely to differ from SUVmax using Bland-Altman plot.
Method:
A total of 53 patients (35 males, 18 females; mean age, 67+-8 y) with pancreas cancer underwent F-18-FDG PET/CT scan in pre-and post-carbon ion radiotherapy. All patients were followed more than 1 year after treatment. The following parameters were measured: maximum standardized uptake value (SUVmax) and peak SUVs (SUVpeak6, SUVpeak10, SUVpeak15). SUVpeak6, SUVpeak10 and SUVpeak15 are measured using spherical VOI with radius 6 mm, 10 mm and 15 mm, respectively, where the volume of spherical VOI of SUVpeak6 is almost 1 cm3. The overall survival was estimated using the Kaplan-Meier method with SUVs as prognostic variables. Bland-Altman plots were used to evaluate difference between SUVmax and SUVpeak in pre-and post-treatment scan.
Results:
Cutoff values for each SUV were defined by ROC analysis, and the probability of survival was significantly lower with increasing FDG uptake measured by all the kinds of SUVs in both pre-and post-treatment.
Significant correlations were observed between SUVmax and SUVpeak6, SUVpeak10 or SUVpeak15 in both pre-and post-treatment. However, proportional bias was observed between SUVmax and SUVpeak6, SUVpeak10 or SUVpeak15 in both pre-and post-treatment as revealed by the Bland-Altman plot analysis. The Bland-Altman analysis illustrated that the 95% limits of agreement is smaller between SUVmax and SUVpeak6 (range: pre 0.25, post 0.16) than between SUVmax and SUVpeak10 (range: pre 0.40, post 0.23), and is also smaller between SUVmax and SUVpeak10 than between SUVmax and SUVpeak15 (rang: 0.62, post 0.35).
Conclusions:
SUVmax and SUVpeak were statistically significant prognostic variables for overall survival estimated using the Kaplan-Meire method. SUVmax as FDG-PET uptake parameter was correlated closely to SUVpeak, but there was proportional bias between SUVmax and SUVpeak. The smaller the sphere's radius of SUVpeak the smaller the 95% limits of agreement is.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 EANM'13 - Annual Congress of the European Association of Nuclear Medicine
発表年月日
日付 2013-10-23
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:52:38.193626
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3