Dose, LET and Ion Species Dependence for PLDR in Normal Human Embryo Fibroblasts

https://repo.qst.go.jp/records/71308
https://repo.qst.go.jp/records/71308
7e49f629-e2a4-4473-9a39-cc988ea04cea
Item type 会議発表用資料 / Presentation(1)
公開日 2013-10-23
タイトル
タイトル Dose, LET and Ion Species Dependence for PLDR in Normal Human Embryo Fibroblasts
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 劉, 翠華

× 劉, 翠華

WEKO 701048

劉, 翠華

Search repository
鶴岡, 千鶴

× 鶴岡, 千鶴

WEKO 701049

鶴岡, 千鶴

Search repository
アッサワプロンポーン, ナロンチャイ

× アッサワプロンポーン, ナロンチャイ

WEKO 701050

アッサワプロンポーン, ナロンチャイ

Search repository
金子, 由美子

× 金子, 由美子

WEKO 701051

金子, 由美子

Search repository
村上, 健

× 村上, 健

WEKO 701052

村上, 健

Search repository
劉 翠華

× 劉 翠華

WEKO 701053

en 劉 翠華

Search repository
鶴岡 千鶴

× 鶴岡 千鶴

WEKO 701054

en 鶴岡 千鶴

Search repository
アッサワプロンポーン ナロンチャイ

× アッサワプロンポーン ナロンチャイ

WEKO 701055

en アッサワプロンポーン ナロンチャイ

Search repository
金子 由美子

× 金子 由美子

WEKO 701056

en 金子 由美子

Search repository
村上 健

× 村上 健

WEKO 701057

en 村上 健

Search repository
抄録
内容記述タイプ Abstract
内容記述 In the present study, we conducted an-in deep study of the role of radiation quality (LET), radiation dose and ion species in modulating the PLDR in human cells exposed to low-or high-LET radiations. Cells were irradiated with various types of radiation and the LET values ranged from ~2.2 to 400 keV/um. Cell-killing efficiencies were measured using a colony-formation assay at immediately (IP, 5-10 min) or delayed plating (DP, 24 h) after irradiation. The PLDR was calculated by the ratio of surviving fractions (DP/IP) at different doses or isosurvival dose of IP. As expected, PLDR decreased with increase LET and when LET was higher than ~200keV/µm; there are little PLDR in all types of radiation and doses. Moreover, there are a minor PLDR in low-dose of all types of radiation used. Interestingly, the results showed that the PLDR of carbon ions is higher than that of helium ions, On the other hand the PLDR of Silicon is higher than other kinds of ions-beams comparing with similar LET radiations. Those results indicated that PLDR is not only depended on LET, but also dependent on radiation doses and ion species.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 日本放射線影響学会第56回大会
発表年月日
日付 2013-10-20
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:52:45.876333
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3