P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the 3D fast scanning system with pencil beams at HIMAC

https://repo.qst.go.jp/records/71276
https://repo.qst.go.jp/records/71276
53ba4c94-8182-4550-bbfe-141e3a6d1236
Item type 会議発表用資料 / Presentation(1)
公開日 2013-10-07
タイトル
タイトル P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the 3D fast scanning system with pencil beams at HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Suzuki, Masao

× Suzuki, Masao

WEKO 700714

Suzuki, Masao

Search repository
Funayama, Tomoo

× Funayama, Tomoo

WEKO 700715

Funayama, Tomoo

Search repository
Yokota, Yuichiro

× Yokota, Yuichiro

WEKO 700716

Yokota, Yuichiro

Search repository
Mutoh, Yasuko

× Mutoh, Yasuko

WEKO 700717

Mutoh, Yasuko

Search repository
Suzuki, Michiyo

× Suzuki, Michiyo

WEKO 700718

Suzuki, Michiyo

Search repository
Ikeda, Hiroko

× Ikeda, Hiroko

WEKO 700719

Ikeda, Hiroko

Search repository
Hattori, Yuya

× Hattori, Yuya

WEKO 700720

Hattori, Yuya

Search repository
Kobayashi, Yasuhiko

× Kobayashi, Yasuhiko

WEKO 700721

Kobayashi, Yasuhiko

Search repository
鈴木 雅雄

× 鈴木 雅雄

WEKO 700722

en 鈴木 雅雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 We constructed the new treatment facility for the advanced carbon-ion therapy applying a 3D fast spot scanning system with pencil beams at HIMAC in NIRS. To identify biological effects of the system, we demonstrated the cell killing of different human tumor cell lines using the spot scanning of carbon-ion microbeams generated with Takasaki Ion Accelerators for Advanced Radiation Application in JAEA and irradiated just 0.04% of total cells by the highly controlled microbeam. The percent survival in the cells with wild-type P53 gene was 89%, while almost 100% was observed in the cells with mutated-type P53 gene. We can expect the percent of 99.96% when the cell killing was induced by the just irradiated 0.04% cells. However, the 89% was significantly low beyond our estimation. Moreover, it returned to 100% when using a specific inhibitor of gap-junction mediated cell-cell communication. There is clear evidence that the spot scanning irradiation of carbon ions enables the enhanced cell killing in wild-type-P53 cells via gap-junction mediated bystander effect. (This is the co-operative study with Drs. T.Funayama, Y.Mutou, M.Suzuki, H.Ikeda, Y.Hattori and Y.Kobayashi in JAEA.)
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第72回日本癌学会学術総会
発表年月日
日付 2013-10-05
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:53:07.609919
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3