ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Carbonion Scanning Lung Therapy (with Respiratory-gated Phase Controlled Rescanning): Simulation Study for 4D Treatment Planning

https://repo.qst.go.jp/records/71269
https://repo.qst.go.jp/records/71269
2524675e-e17f-4aff-adee-17927d99f5ad
Item type 会議発表用資料 / Presentation(1)
公開日 2013-09-30
タイトル
タイトル Carbonion Scanning Lung Therapy (with Respiratory-gated Phase Controlled Rescanning): Simulation Study for 4D Treatment Planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takahashi, Wataru

× Takahashi, Wataru

WEKO 700598

Takahashi, Wataru

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 700599

Mori, Shinichiro

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 700600

Furukawa, Takuji

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 700601

Inaniwa, Taku

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 700602

Nakajima, Mio

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 700603

Shirai, Toshiyuki

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 700604

Noda, Kouji

Search repository
Yamamoto, Naoyoshi

× Yamamoto, Naoyoshi

WEKO 700605

Yamamoto, Naoyoshi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 700606

Kamada, Tadashi

Search repository
高橋 渉

× 高橋 渉

WEKO 700607

en 高橋 渉

Search repository
森 慎一郎

× 森 慎一郎

WEKO 700608

en 森 慎一郎

Search repository
古川 卓司

× 古川 卓司

WEKO 700609

en 古川 卓司

Search repository
稲庭 拓

× 稲庭 拓

WEKO 700610

en 稲庭 拓

Search repository
中嶋 美緒

× 中嶋 美緒

WEKO 700611

en 中嶋 美緒

Search repository
白井 敏之

× 白井 敏之

WEKO 700612

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 700613

en 野田 耕司

Search repository
山本 直敬

× 山本 直敬

WEKO 700614

en 山本 直敬

Search repository
鎌田 正

× 鎌田 正

WEKO 700615

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose/Objective(s)
To provide mostly satisfactory dose conformity to the moving target, we applied a respiratorygated strategy to the carbonion active scanning lung treatment with multiple phase controlled rescannings (PCR). Here, we quantified the dose assessment using 4DCT data set.
Materials/Methods
Total 14 patients with lung tumor (stage I nonsmallcell lung cancer or oligometastatic lung tumor) were randomly selected. Volumetric cine CT images were acquired in 4D mode under free breathing conditions. Pencilbeam scanning carbonion radiotherapy (PBSCIRT) plans were created for each patient.
The gross tumor volume, the clinical target volume (CTV) and organ at risks (OARs) were delineated. Fieldspecific target volumes (FTVs) were calculated for respective beam fields two types of FTVs were designed for ungated (full respiratory cycle) and gated (T40T60) strategies. The prescribed dose of 48Gy(RBE) in single fraction was given to the FTVs with different coplanar four angles.
As technique of irradiation for moving target, two methods were used in current study (1) respiratory gating for motion mitigation, (2) PCR to obtain a conformal dose distribution. We evaluated the dose metrics by changing the number of PCRs and compared them in between ungated and gated strategies. To calculate the accumulated dose distribution, the deformable image registration was applied to transfer dose distributions at respective phases to the reference phase.
Results
By defining of FTV, undershooting to the target could be generally avoided in each respiratory phase. As shown in Table, D95 of the treatment dose was 94.4+-1.9% even in 1x PCR ungated plan.
In gating plan, significant improvements in all the dose volume indices of CTV and OARs were found compared with ungated plan.
Moreover, observe that the CTV coverage improved gradually as the number of PCR increased. 4 times or more of PCR resulted in adequate target coverage.
As for OARs, the dose indices of lung V20, Dmax of heart and spinal cord did not change significantly according to increasing PCR. These metrics were improved only with respiratory gating. For instance, dose to lung V20 was decreased 12% (4.3Gy(RBE) in ungated plan to 3.8Gy(RBE) in gated).
Conclusions
For a moving target, PBSCIRT system with gating and PCR accurately achieve homogenous dose distribution even in actual patients.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ASTRO's 55th Annual Meeting
発表年月日
日付 2013-09-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:53:13.225475
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3