ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

RADIF- NIRS System for Measurement of Radon Diffusion in Membranes

https://repo.qst.go.jp/records/71241
https://repo.qst.go.jp/records/71241
0d160da3-a7f1-4a77-bc87-b4ca29344ed1
Item type 会議発表用資料 / Presentation(1)
公開日 2013-09-17
タイトル
タイトル RADIF- NIRS System for Measurement of Radon Diffusion in Membranes
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Miroslaw, JANIK

× Miroslaw, JANIK

WEKO 700301

Miroslaw, JANIK

Search repository
Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 700302

Ishikawa, Tetsuo

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 700303

Yonehara, Hidenori

Search repository
ミロソラフ ヤニック

× ミロソラフ ヤニック

WEKO 700304

en ミロソラフ ヤニック

Search repository
石川 徹夫

× 石川 徹夫

WEKO 700305

en 石川 徹夫

Search repository
米原 英典

× 米原 英典

WEKO 700306

en 米原 英典

Search repository
抄録
内容記述タイプ Abstract
内容記述 The new system for measurement of radon diffusion constant in membranes (RADIF) is established at the National Institute of Radiological Sciences (NIRS), Japan.
The RADIF system consists of several components: two AB-5 radiation monitors (uses proven photomultiplier tube (PMT) technology) connected to source and receiver chambers, with volume of 30 and 100 dm3, respectively, ceramic radon source and AlphaGUARD device for radon monitoring outside chambers as well as environmental parameters registration.
The permeability of membranes is measured according to the ISO norm and method entitled "Determining the radon diffusion coefficient under stationary conditions established during ventilation of the receiver container" (ISO/WD 11665-10).
Under this condition the radon concentration in the source container is stable whereas the radon increases in the receiver container. Finally, the permeability (diffusion coefficient) of the investigated membrane is derived using one-dimensional stationary radon diffusion described by the differential equation.
Moreover, due to relatively large volumes of both containers (source and receiver) the investigation of diffusion process in relation to changeability of environmental parameters (humidity and temperature) is also possible.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 7th International Conference on Protection Against Radon at Home and at Work
発表年月日
日付 2013-09-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:53:32.410566
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3