ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Development of fast scanning magnets and their power supply for particle therapy

https://repo.qst.go.jp/records/71201
https://repo.qst.go.jp/records/71201
86b474a3-0f62-4f0c-9180-f0a7572723b4
Item type 会議発表用資料 / Presentation(1)
公開日 2013-07-26
タイトル
タイトル Development of fast scanning magnets and their power supply for particle therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furukawa, Takuji

× Furukawa, Takuji

WEKO 699964

Furukawa, Takuji

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 699965

Shirai, Toshiyuki

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 699966

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 699967

Satou, Shinji

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 699968

Mizushima, Kota

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 699969

Noda, Kouji

Search repository
et.al

× et.al

WEKO 699970

et.al

Search repository
古川 卓司

× 古川 卓司

WEKO 699971

en 古川 卓司

Search repository
白井 敏之

× 白井 敏之

WEKO 699972

en 白井 敏之

Search repository
稲庭 拓

× 稲庭 拓

WEKO 699973

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 699974

en 佐藤 眞二

Search repository
水島 康太

× 水島 康太

WEKO 699975

en 水島 康太

Search repository
野田 耕司

× 野田 耕司

WEKO 699976

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 At Heavy Ion Medical Accelerator in Chiba (HIMAC), more than 8000 patients have been successfully treated by carbon ion beams since 1994. The successful results of treatments have led us to construct a new treatment facility equipped with three-dimensional pencil beam scanning irradiation system. For implementation of this irradiation technique, we developed fast scanning magnet and their supply, which are required to have field ramp rate of more than 250 T/s. The scanning magnets set at the entrance of the irradiation system are two dipole magnets to scan the beam in both horizontal and vertical directions, and used to form the irradiation field to be tumor shape. Before the installation, performance test including both static and dynamic field measurement was carried out. Severe delay of the field and temperature rise were not observed as expected. Measured field ramp rate reached up to 300 T/s. After the installation, we verified the accuracy and stability of the scanned ion beam through the commissioning with the beam. As a successful result of the commissioning, treatment using new scanning system was started in 2011.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Conference on Magnet Technology (MT-23)
発表年月日
日付 2013-07-19
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:54:02.363308
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3