Measurement of neutron ambient dose equivalent in carbon-ion radiotherapy with active scanned beam

https://repo.qst.go.jp/records/71150
https://repo.qst.go.jp/records/71150
432e1ede-fc06-427d-8ea5-5d2dd057fa92
Item type 会議発表用資料 / Presentation(1)
公開日 2013-06-14
タイトル
タイトル Measurement of neutron ambient dose equivalent in carbon-ion radiotherapy with active scanned beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 699452

Yonai, Shunsuke

Search repository
et.al

× et.al

WEKO 699453

et.al

Search repository
米内 俊祐

× 米内 俊祐

WEKO 699454

en 米内 俊祐

Search repository
抄録
内容記述タイプ Abstract
内容記述 In ion beam radiotherapy, out-of-field dose due to secondary neutrons as well as leakage charged particles is considerably lower than in-field dose, but it may be not negligible to estimate the secondary cancer risk especially for the young patients. In National Institute of Radiological Sciences (NIRS), out-of-field dose in carbon-ion radiotherapy with passive beam is continuously investigated. Also, in the previous paper, we showed that active scanned beam can reduce the out-of-field dose compared to passive beam by Monte Carlo simulation.[1] In this study, neutron ambient dose equivalents in carbon-ion radiotherapy with active beam were measured with a rem meter at the new treatment research facility in NIRS where the treatment with active beam was started in May 2011, and then were compared to those with passive beam.[2] Measurements were performed with WENDI-II for 290 and 400 MeV/u carbon beams. A water phantom was placed to simulate a patient at the isocenter (I.C.). The center of WENDI-II was set to be at the I.C. height and on the I.C. line orthogonal to the beam axis. The measured position represented by the distance between the I.C. and the center of WENDI-II, d, was varied from 50 to 200 cm. When the target volume is the same, the neutron dose with active beam was about 15% of that with passive beam at a maximum. This decrease was larger as the position became farther from the I.C. The neutron dose at d=200 cm with active beam was only 4% of that with passive beam. In conclusion, we experimentally demonstrated that the use of active scanning beam in carbon ion radiotherapy can greatly reduce the secondary neutron dose which contributes most to out-of-field dose.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NEUDOS12
発表年月日
日付 2013-06-07
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:54:37.077662
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3