Renewal of reference line for the rectal dose constraints in carbon therapy for prostate cancer

https://repo.qst.go.jp/records/71145
https://repo.qst.go.jp/records/71145
aa9febf2-78c2-4e1d-ac71-277420af6014
Item type 会議発表用資料 / Presentation(1)
公開日 2013-06-13
タイトル
タイトル Renewal of reference line for the rectal dose constraints in carbon therapy for prostate cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fukahori, Mai

× Fukahori, Mai

WEKO 699364

Fukahori, Mai

Search repository
Himukai, Takeshi

× Himukai, Takeshi

WEKO 699365

Himukai, Takeshi

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 699366

Matsufuji, Naruhiro

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 699367

Kanematsu, Nobuyuki

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 699368

Tsuji, Hiroshi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 699369

Kamada, Tadashi

Search repository
深堀 麻衣

× 深堀 麻衣

WEKO 699370

en 深堀 麻衣

Search repository
日向 猛

× 日向 猛

WEKO 699371

en 日向 猛

Search repository
松藤 成弘

× 松藤 成弘

WEKO 699372

en 松藤 成弘

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 699373

en 兼松 伸幸

Search repository
辻 比呂志

× 辻 比呂志

WEKO 699374

en 辻 比呂志

Search repository
鎌田 正

× 鎌田 正

WEKO 699375

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Aim:
The radiation injury of the rectum is the major concern in radiotherapy for prostate cancer because it often threatens a patient's QOL. There are many references available for the dose constraints in conventional radiotherapy, however, no clear index has been established for carbon ion therapy. At NIRS, rectal DVH [cc] based on clinical outcomes in 20 fractions in 5 weeks has been used as the dose constraint (reference line) in evaluating treatment plans. Since 2008, new clinical protocol has been performed for prostate cancer to reveal the efficacy of hypofractionation from the 20 fractions to 16 fractions in 4 weeks. Furthermore, dose calculation algorithm has been updated from broad beam calculation (HIPLAN) to pencil beam calculation (XiO-N) in 2012. The aim of this study is to update reference line of the rectal DVH for prostate cancer to be applicable for the new fractionation protocol and treatment planning system (TPS).
Method:
The new reference line was derived based on 36 patients developed rectum injury treated with 57.6 Gy (RBE) in 16 fractions between May 2003 and May 2010. After transferring the plans of the patients from HIPLAN to XiO-N, these plans were recalculated and made dose-volume histograms (DVHs) of rectum were evaluated. The new rectum reference line was set as the average of all the DVH curves. In order to assess the appropriateness of the new reference line, DVHs of 3 patients who did not develop the rectum injury were derived and compared.
Results:
The new reference line for 16 fractions gives reduced dose than the old one. It was also found that DVH [%] showed more significant relation to the occurrence of rectum injury than DVH [cc].
Conclusions:
Our new reference line of the rectal DVH for carbon ion radiotherapy of prostate cancer is derived and confirmed adequate for the new fraction protocol. It has been installed in the new TPS in terms of DVH [cc] as well as DVH [%] in order to support for doctors checking the treatment plans since September 2012.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 52nd Annual Conference of the Particle Therapy Co-Operative Group(PTCOG52)
発表年月日
日付 2013-06-08
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:54:40.535923
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3