Updating of HIMAC Beam Delivery with Broad Beam Method
https://repo.qst.go.jp/records/71099
https://repo.qst.go.jp/records/710999c4ff2f9-04d3-472c-94b0-f6fe82a80dfa
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-05-21 | |||||
タイトル | ||||||
タイトル | Updating of HIMAC Beam Delivery with Broad Beam Method | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizota, Manabu
× Mizota, Manabu× 溝田 学 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Carbon ion radiotherapy at HIMAC started in 1994 using two horizontal and two vertical beam ports with broad beam method. The maximum beam energy extracted from accelerators was 400 MeV/n for the horizontal beam port, and 350 MeV/n for the vertical one. In recent years the scope of diseases that can be treated by the carbon ion radiotherapy has widened and their tumor targets have varied in dimension and location. So, situations of shortage in the beam range in treatment planning have increased. In order to provide sufficient dose to the deeply-seated target, we adopted higher energy beam, that is, 430 MeV/n and 400 MeV/n for the horizontal port and the vertical port, respectively. For the introduction of the new energy beams, we carried out the following. (1) Adjustment of new parameter-sets of the accelerators for the high-energy beams. (2) Replacement of ridge filters with the redesigned ones for the high-energy beams. (3) Updating irradiation condition tables in the irradiation control system and registering new beam data in the treatment planning system, on the base of dose distribution measurements. As a result, the beam range for horizontal port and vertical port was extended approximately 30 mm and 50 mm, respectively. This enables to treat all patients without ingenuity of patient's posturing and beam weight for each direction. On the other hand, adding new operational energies leads to a decrease in whole throughput, since it takes time to switch among the beam energies. We have at the same time simplified the procedures for the dose calibration and beam adjustment in the switching of energy. The broad beam method has reached maturity as a standard irradiation method of carbon ion radiotherapy and has achieved superior clinical results. We will continue to make upgrades this system with maintenance of its performance and improve the usability of this systems. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 国際重粒子線シンポジウム2013 in Chiba | |||||
発表年月日 | ||||||
日付 | 2013-05-18 | |||||
日付タイプ | Issued |