Updating of HIMAC Beam Delivery with Broad Beam Method

https://repo.qst.go.jp/records/71099
https://repo.qst.go.jp/records/71099
9c4ff2f9-04d3-472c-94b0-f6fe82a80dfa
Item type 会議発表用資料 / Presentation(1)
公開日 2013-05-21
タイトル
タイトル Updating of HIMAC Beam Delivery with Broad Beam Method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizota, Manabu

× Mizota, Manabu

WEKO 698826

Mizota, Manabu

Search repository
溝田 学

× 溝田 学

WEKO 698827

en 溝田 学

Search repository
抄録
内容記述タイプ Abstract
内容記述 Carbon ion radiotherapy at HIMAC started in 1994 using two horizontal and two vertical beam ports with broad beam method. The maximum beam energy extracted from accelerators was 400 MeV/n for the horizontal beam port, and 350 MeV/n for the vertical one. In recent years the scope of diseases that can be treated by the carbon ion radiotherapy has widened and their tumor targets have varied in dimension and location. So, situations of shortage in the beam range in treatment planning have increased.
In order to provide sufficient dose to the deeply-seated target, we adopted higher energy beam, that is, 430 MeV/n and 400 MeV/n for the horizontal port and the vertical port, respectively. For the introduction of the new energy beams, we carried out the following.
(1) Adjustment of new parameter-sets of the accelerators for the high-energy beams.
(2) Replacement of ridge filters with the redesigned ones for the high-energy beams.
(3) Updating irradiation condition tables in the irradiation control system and registering new beam data in the treatment planning system, on the base of dose distribution measurements.
As a result, the beam range for horizontal port and vertical port was extended approximately 30 mm and 50 mm, respectively. This enables to treat all patients without ingenuity of patient's posturing and beam weight for each direction.
On the other hand, adding new operational energies leads to a decrease in whole throughput, since it takes time to switch among the beam energies. We have at the same time simplified the procedures for the dose calibration and beam adjustment in the switching of energy.
The broad beam method has reached maturity as a standard irradiation method of carbon ion radiotherapy and has achieved superior clinical results. We will continue to make upgrades this system with maintenance of its performance and improve the usability of this systems.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 国際重粒子線シンポジウム2013 in Chiba
発表年月日
日付 2013-05-18
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:55:12.699954
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3