Timing Analysis of the Xtal Cube PET Detector Based on Six-Surface Readout Using 96 MPPCs
https://repo.qst.go.jp/records/70985
https://repo.qst.go.jp/records/709858240238b-3a45-469f-923f-60ce1c42dc46
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-11-19 | |||||
タイトル | ||||||
タイトル | Timing Analysis of the Xtal Cube PET Detector Based on Six-Surface Readout Using 96 MPPCs | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nishikido, Fumihiko
× Nishikido, Fumihiko× Hirano, Yoshiyuki× Yoshida, Eiji× Inadama, Naoko× Murayama, Hideo× Ito, Hiroshi× Yamaya, Taiga× 錦戸 文彦× 平野 祥之× 吉田 英治× 稲玉 直子× 村山 秀雄× 伊藤 浩× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We are developing the next generation depth-of-interaction detector, X'tal cube, with isotropic and high spatial resolution for positron emission tomography (PET). The X'tal cube consists of a crystal block optically segmented three-dimensionally without any reflector insertion. 4x4 multi-pixel photon counter (MPPC) arrays cover all six surfaces of the crystal block. The six-surface readout can obtain rich position information, and it is expected to realize high isotropic spatial resolution. On the other hand, a large number of readout at various photodetector positions could effect on the timing resolution. From the perspective, we studied the timing characteristics of the X'tal cube detector. To obtain the details of the timing information, we used a measurement system which consisted of two digital oscilloscopes (DPS7104, Tektronix) and a standard NIM/CAMAC system. The timing information was acquired from six sum signals of the 16 MPPCs on each surface with summing amplifiers. These signals were digitalized and recorded by two digital oscilloscopes. Signals from the BaF2 were also recorded with the oscilloscope, which was used as the start signals of the coincidence timing. We used the 96ch MPPC signals individually recorded by CAMAC ADCs synchronized with the digital oscilloscopes to create flood histograms and energy spectra. Results showed that pulse shapes of the output signals and timing information from each surface clearly depended on the interacted crystal position. In addition, timing resolution was improved by selecting the optimum combination of the readout signals of each surface. | |||||