タイトル X-Ray Detector Made of Plastic Scintillators and WLS Fiber for Real-Time Dose Distribution Monitoring in Interventional Radiology
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 697714

Nishikido, Fumihiko

Search repository
et.al

× et.al

WEKO 697715

et.al

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 697716

en 錦戸 文彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Interventional radiology (IVR) is a medical subspecialty of radiology to realize image-guided surgical procedures using imaging modalities, such as x-ray fluoroscopy. Recently, IVR is increasingly used in treatment of vascular lesions due to its low invasiveness. On the other hand, skin injuries due to prolonged x-ray exposure during the procedure have been reported. Therefore, monitoring of skin dose is desired in clinical sites for reduction of excessive x-ray exposure. We propose a real time dose distribution monitor for IVR. Some scintillation detectors which consist of low stopping power materials, such as plastic scintillators, are placed on a stretchable cap which can be worn by the patient. Scintillation light is fed to photo detectors outside the FOV through plastic optical fibers. This arrangement means that there are only radiolucent materials in the FOV and the proposed dose monitor does not interfere with the IVR procedure. As a result, the proposed monitor realizes real-time monitoring of the dose distribution on the patients skin. As the first step, we are developing a prototype x-ray detector element which consists of plastic scintillators and a wavelength shifting (WLS) fiber connected to the optical fiber. The square shaped WLS fiber is sandwiched by two plastic scintillators with a plate shape and dimensions of 10.0 mm x 4.5 mm x 1.0 mm. Scintillation light generated in the plastic scintillators is captured and converted to different wavelength light in the WLS fiber. The converted photons are transported to a MPPC through the 1 m length optical fiber which has the same diametrical size as the WLS fiber. We conducted evaluation experiments of detector performance with synchrotron-generated X-rays in the beamline BL-14A at the Photon Factor and micro CT (R_mCT2, RIGAKU) operating in the projection mode. The experimental results indicated that the proposed detector can measure X-ray doses in real-time with at least a 30 s interval.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2012IEEE NSS&MIC
発表年月日
日付 2012-11-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:56:32.708156
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3