ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

MicroPET/CT imaging of orthotopic pancreatic tumor-bearing mice using the integrin tracer 64Cu-labeled cyclam-RAFT-c(-RGDfK-)4 peptide

https://repo.qst.go.jp/records/70888
https://repo.qst.go.jp/records/70888
b22a6b94-1b86-4ff9-811b-855bc6027368
Item type 会議発表用資料 / Presentation(1)
公開日 2012-09-12
タイトル
タイトル MicroPET/CT imaging of orthotopic pancreatic tumor-bearing mice using the integrin tracer 64Cu-labeled cyclam-RAFT-c(-RGDfK-)4 peptide
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 U, Winn Aung

× U, Winn Aung

WEKO 696590

U, Winn Aung

Search repository
Jin, Zhao-Hui

× Jin, Zhao-Hui

WEKO 696591

Jin, Zhao-Hui

Search repository
Furukawa, Takako

× Furukawa, Takako

WEKO 696592

Furukawa, Takako

Search repository
Sogawa, Chizuru

× Sogawa, Chizuru

WEKO 696593

Sogawa, Chizuru

Search repository
Tsuji, Atsushi

× Tsuji, Atsushi

WEKO 696594

Tsuji, Atsushi

Search repository
Wakizaka, Hidekatsu

× Wakizaka, Hidekatsu

WEKO 696595

Wakizaka, Hidekatsu

Search repository
Fukumura, Toshimitsu

× Fukumura, Toshimitsu

WEKO 696596

Fukumura, Toshimitsu

Search repository
Coll, Jean-Luc

× Coll, Jean-Luc

WEKO 696597

Coll, Jean-Luc

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 696598

Saga, Tsuneo

Search repository
et.al

× et.al

WEKO 696599

et.al

Search repository
U Winn Aung

× U Winn Aung

WEKO 696600

en U Winn Aung

Search repository
金 朝暉

× 金 朝暉

WEKO 696601

en 金 朝暉

Search repository
古川 高子

× 古川 高子

WEKO 696602

en 古川 高子

Search repository
曽川 千鶴

× 曽川 千鶴

WEKO 696603

en 曽川 千鶴

Search repository
辻 厚至

× 辻 厚至

WEKO 696604

en 辻 厚至

Search repository
脇坂 秀克

× 脇坂 秀克

WEKO 696605

en 脇坂 秀克

Search repository
福村 利光

× 福村 利光

WEKO 696606

en 福村 利光

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 696607

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective: Pancreatic cancer has the worst prognosis among solid tumors. Early diagnosis and efficient therapeutic measure remain as the major challenges. A suitable animal model that mimics the clinical situation as closely as possible is essential for developing and comparing new diagnostic and therapeutic strategies. A new PET imaging probe, 64Cu-labeled cyclam-RAFT-c(-RGDfK-)4 (64Cu-RAFT-RGD) peptide has been examined for visualization and quantification of avB3 integrin expression in animal tumor models by our group. The purpose of this study is to develop a clinically relevant orthotopic xenotransplantation model of pancreatic cancer that reflects the clinical situation and to perform preclinical evaluation of 64Cu-RAFT-RGD probe, allowed in this model. Methods: Expression of avB3 integrin in several human pancreatic cancer cell lines was examined by flow cytometry and Western blotting. The representative cell line BxPC-3 which was stably transfected with red fluorescence reporter protein (RFP) that could be detected with optical imaging system, was used for surgical orthotopic implantation. In vivo probe biodistribution and receptor blocking study, preclinical PET imaging co-registered with contrast enhanced computed tomography (CECT) comparing 64Cu-RAFT-RGD and 18F-FDG accumulation in tumor, post imaging ex vivo autoradiography and histological examination were done. Results: Most of pancreatic cancer cell lines showed integrin avB3 expression. Orthotopic xenograft was established in pancreas of recipient nude mice by implantation of a piece of subcutaneous tumor developed in donor mice. In vivo biodistribution with blocking study confirmed that the efficient binding of probe to tumor is highly avB3 integrin specific. 64Cu-RAFT-RGD PET imaging combined with CECT that provided anatomical delineation of tumor, encouraged for precise and easy detection of pancreatic cancer lesion. In comparative PET study, 64Cu-RAFT-RGD accumulation provided better tumor contrast to background than 18F-FDG. Post imaging autoradiography and histological examination validated the accumulation of 64Cu-RAFT-RGD probe in tumor versus non-tumor tissues. Conclusion: Our results suggest that 64Cu-RAFT-RGD PET imaging can be potentially applicable for the diagnosis of avB3-expressing pancreatic cancer.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2012 World Molecular Imaging Congress
発表年月日
日付 2012-09-08
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:57:39.912534
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3