Establishment of a dose-response curve of 60Co gamma-ray irradiation by dicentric chromosome analysis

https://repo.qst.go.jp/records/70778
https://repo.qst.go.jp/records/70778
8b63e16c-2299-4c92-9de8-f2aa5f8a2e07
Item type 会議発表用資料 / Presentation(1)
公開日 2012-05-29
タイトル
タイトル Establishment of a dose-response curve of 60Co gamma-ray irradiation by dicentric chromosome analysis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Suto, Yumiko

× Suto, Yumiko

WEKO 695344

Suto, Yumiko

Search repository
Akiyma, Miho

× Akiyma, Miho

WEKO 695345

Akiyma, Miho

Search repository
Hirai, Momoki

× Hirai, Momoki

WEKO 695346

Hirai, Momoki

Search repository
Sugiura, Nobuyuki

× Sugiura, Nobuyuki

WEKO 695347

Sugiura, Nobuyuki

Search repository
et.al

× et.al

WEKO 695348

et.al

Search repository
數藤 由美子

× 數藤 由美子

WEKO 695349

en 數藤 由美子

Search repository
穐山 美穂

× 穐山 美穂

WEKO 695350

en 穐山 美穂

Search repository
平井 百樹

× 平井 百樹

WEKO 695351

en 平井 百樹

Search repository
杉浦 紳之

× 杉浦 紳之

WEKO 695352

en 杉浦 紳之

Search repository
抄録
内容記述タイプ Abstract
内容記述 Ionizing radiation exposure causes DNA strand breaks that lead to chromosome aberrations. Among radiation-induced chromosome aberrations, multicentric chromosomes, as represented by dicentric chromosomes, are considered to be sensitive and specific biomarkers for assessing the radiation dose. For more than three decades, dicentric chromosome analysis (DCA) has been the Gold Standard of biodosimetry. In DCA, a dicentric yield per cell of a radiation-exposed patient is applied to a calibration curve (dose-response curve). Many dose-response curves have been proposed thus far, but most of them have been generated respectively from one healthy donor by one in vitro experiment. According to the result of international collaborative works on inter-laboratory comparisons, it has been reported that in DCA, the significant variation of dose estimation is partly attributed to different experimental protocols including the scoring criteria of chromosome aberrations among institutions / investigators. Thus, it is necessary for a biodosimetry laboratory to have and use its own dose-response curve under its own experimental conditions.
In the present study, in order to evaluate the dose estimation of patients for better medical preparedness, a dose-response curve was established by analyzing 13 occupationally non-exposed healthy volunteers by DCA using peripheral blood samples irradiated in vitro with 60Co gamma-rays at seven different doses (0, 0.5, 1.0, 2.0, 3.0, 4.0 and 5.0 Gy). The result of the first-division metaphase scoring followed a linear-quadratic equation, Y=A+aD+bD2 (Y: the yield of dicentrics, D: the dose, A: the background frequency, a: the linear coefficient, b: the dose squared coefficient; IAEA Technical Reports Series No. 405 Cytogenetic Analysis for Radiation Dose Assessment, Vienna, 2001).
Then, we established a practical biodosimetry protocol for radiation emergency medicine, tentatively called the NIRS DCA System (including sample collection, cell culture, chromosome preparation, automated metaphase image-capturing, chromosome aberration scoring in triage- and full estimation-modes, and a diagnostic report format), for conducting dose estimation within several days of receiving blood samples. The NIRS DCA System is now being used for actual radiation exposure accidents in Japan.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 the 13th International Congress of the International Radiation Protection Association
発表年月日
日付 2012-05-18
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:58:57.148258
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3