WEKO3
アイテム
Pilot Study for Standardization of RBE Intercomparison of Hadron Therapy Beams in vitro
https://repo.qst.go.jp/records/70534
https://repo.qst.go.jp/records/7053405a731ca-7449-48f8-b129-4b0455bbe3af
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-09-16 | |||||
タイトル | ||||||
タイトル | Pilot Study for Standardization of RBE Intercomparison of Hadron Therapy Beams in vitro | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Uzawa, Akiko
× Uzawa, Akiko× Vischioni, Barbara× Koike, Sachiko× Hirayama, Ryoichi× Matsumoto, Yoshitaka× Tsuruoka, Chizuru× Furusawa, Yoshiya× 鵜澤 玲子× Vischioni Barbara× 小池 幸子× 平山 亮一× 松本 孔貴× 鶴岡 千鶴× 古澤 佳也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Cancer therapy with carbon ions at the HIMAC has started in 1994, more than 5,000 lesions have been treated by 2010, and fruitful results have been demonstrated. Following those results, few heavy-ion treatment facilities are working, some are under construction and many new facilities are planning all over the world now. To start treatments with HIMAC clinical experiences such as treatment planning, the beam quality at those new facilities must be very similar to the HIMAC in physics and biology. Biological results are easy to affected by the biological conditions, techniques or so on. We tried to establish a standard biological protocol for this purpose. Both C3H/He mice bead at NIRS (N) and Charles River Co. (C) were employed, and the crypt cell survival assay 3.5 days after the irradiation was performed with whole body single irradiation of carbon 290 MeV/u beam having 6 cm SOBP at HIMAC. Crypt survival data was taken from (N) and (C) mice, by both trained and fresh observers. The radio-sensitivity of the mice crypt was different by the breeders. The Dq values were similar between them (C and N), but the Do for (N) was higher than that for (C). Recognition level of the existing crypts at counting was different by the observers, but this technical difference was conquerable by simple training. Change in the recognition level with elapsed time could not found for an observer within 6 years. Use of mice supplied by worldwide breeder with good quality control may be required for intercomparison of RBE. Short training could unify technique of new observer. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 14th International Congress of Radiation Research (ICRR2011) | |||||
発表年月日 | ||||||
日付 | 2011-09-01 | |||||
日付タイプ | Issued |