ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Pilot Study for Standardization of RBE Intercomparison of Hadron Therapy Beams in vitro

https://repo.qst.go.jp/records/70534
https://repo.qst.go.jp/records/70534
05a731ca-7449-48f8-b129-4b0455bbe3af
Item type 会議発表用資料 / Presentation(1)
公開日 2011-09-16
タイトル
タイトル Pilot Study for Standardization of RBE Intercomparison of Hadron Therapy Beams in vitro
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Uzawa, Akiko

× Uzawa, Akiko

WEKO 692706

Uzawa, Akiko

Search repository
Vischioni, Barbara

× Vischioni, Barbara

WEKO 692707

Vischioni, Barbara

Search repository
Koike, Sachiko

× Koike, Sachiko

WEKO 692708

Koike, Sachiko

Search repository
Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 692709

Hirayama, Ryoichi

Search repository
Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 692710

Matsumoto, Yoshitaka

Search repository
Tsuruoka, Chizuru

× Tsuruoka, Chizuru

WEKO 692711

Tsuruoka, Chizuru

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 692712

Furusawa, Yoshiya

Search repository
鵜澤 玲子

× 鵜澤 玲子

WEKO 692713

en 鵜澤 玲子

Search repository
Vischioni Barbara

× Vischioni Barbara

WEKO 692714

en Vischioni Barbara

Search repository
小池 幸子

× 小池 幸子

WEKO 692715

en 小池 幸子

Search repository
平山 亮一

× 平山 亮一

WEKO 692716

en 平山 亮一

Search repository
松本 孔貴

× 松本 孔貴

WEKO 692717

en 松本 孔貴

Search repository
鶴岡 千鶴

× 鶴岡 千鶴

WEKO 692718

en 鶴岡 千鶴

Search repository
古澤 佳也

× 古澤 佳也

WEKO 692719

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Cancer therapy with carbon ions at the HIMAC has started in 1994, more than 5,000 lesions have been treated by 2010, and fruitful results have been demonstrated. Following those results, few heavy-ion treatment facilities are working, some are under construction and many new facilities are planning all over the world now. To start treatments with HIMAC clinical experiences such as treatment planning, the beam quality at those new facilities must be very similar to the HIMAC in physics and biology. Biological results are easy to affected by the biological conditions, techniques or so on. We tried to establish a standard biological protocol for this purpose.
Both C3H/He mice bead at NIRS (N) and Charles River Co. (C) were employed, and the crypt cell survival assay 3.5 days after the irradiation was performed with whole body single irradiation of carbon 290 MeV/u beam having 6 cm SOBP at HIMAC. Crypt survival data was taken from (N) and (C) mice, by both trained and fresh observers.
The radio-sensitivity of the mice crypt was different by the breeders. The Dq values were similar between them (C and N), but the Do for (N) was higher than that for (C). Recognition level of the existing crypts at counting was different by the observers, but this technical difference was conquerable by simple training. Change in the recognition level with elapsed time could not found for an observer within 6 years.
Use of mice supplied by worldwide breeder with good quality control may be required for intercomparison of RBE. Short training could unify technique of new observer.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 14th International Congress of Radiation Research (ICRR2011)
発表年月日
日付 2011-09-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:01:48.357792
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3