ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Radiosensitivity in mesothelioma cell lines in X rays and carbon-ion beams

https://repo.qst.go.jp/records/70500
https://repo.qst.go.jp/records/70500
08976311-3a64-468c-b04f-72925955bcdd
Item type 会議発表用資料 / Presentation(1)
公開日 2011-09-05
タイトル
タイトル Radiosensitivity in mesothelioma cell lines in X rays and carbon-ion beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hua, Liu Cui

× Hua, Liu Cui

WEKO 692315

Hua, Liu Cui

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 692316

Suzuki, Masao

Search repository
Autsavapromporn, Narongchai

× Autsavapromporn, Narongchai

WEKO 692317

Autsavapromporn, Narongchai

Search repository
Wada, Mami

× Wada, Mami

WEKO 692318

Wada, Mami

Search repository
Kaneko, Yumiko

× Kaneko, Yumiko

WEKO 692319

Kaneko, Yumiko

Search repository
et.al

× et.al

WEKO 692320

et.al

Search repository
劉 翠華

× 劉 翠華

WEKO 692321

en 劉 翠華

Search repository
鈴木 雅雄

× 鈴木 雅雄

WEKO 692322

en 鈴木 雅雄

Search repository
アッサワプロンポーン ナロンチャイ

× アッサワプロンポーン ナロンチャイ

WEKO 692323

en アッサワプロンポーン ナロンチャイ

Search repository
和田 麻美

× 和田 麻美

WEKO 692324

en 和田 麻美

Search repository
金子 由美子

× 金子 由美子

WEKO 692325

en 金子 由美子

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE:Malignant pleural mesothelioma (MPM) is an aggressive tumor arising from serous surfaces and often related to asbestos exposure. Taking into account a latency period of 20-40 years, it has been estimated that the number of men dying from MPM increase each year until a peak is reached in about 2020. MPM is resistant to various forms of therapy, such as radiotherapy, surgery or chemotherapy, and only slightly improve prognosis. So far, no effective therapeutics including chemotherapy or radiotherapy has been established for the disease-advanced case. The present study was carried out in order to examine the radio-sensitivity of MPM cell lines by X rays and carbon-ion beams.
MATERIALS AND METHODS: Six kinds of MPM cell lines officially distributed by the cell bank were used and irradiated with X rays or carbon-ion beams (13.3keV/µm and approximately 80keV/µm) at the Heavy Ion Medical Accelerator in Chiba (HIMAC) in National Institute of Radiological Sciences (NIRS), Japan. Cell-killing effect was detected using a colony-formation assay.
RESULTS: D10, which is one of the parameters for cellular radio-sensitivity and is determined as the dose (Gy) required to reduce the surviving fraction to 10%, of 6 cell lines ranged from 2.74Gy to 5.42Gy for X rays, 2.17Gy to 4.21Gy for 13keV/µm- and 1.08Gy to 2.38Gy for 80keV/µm-carbon ions. The relative biological effectiveness (RBE) values were calculated by the D10 relative to X rays, ranged from 1.24 to 1.42 for 13keV/µm- and from 2.31 to 3.09 for 80keV/µm-carbon ions on each cell line.
CONCLUSION: The results suggest that the irradiation of high-LET carbon ions is also significantly more effective in cell killing for the 6 kinds of MPM cell lines than that of low-LET X rays.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 14th International Congress of Radiation Research (ICRR’2011)
発表年月日
日付 2011-09-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:02:14.719756
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3